Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Low-cost sensors are often co-located with reference instruments to assess their performance and establish calibration equations, but limited discussion has focused on whether the duration of this calibration period can be optimized. We placed a multipollutant monitor that contained sensors that measure particulate matter smaller than 2.5 μm (PM), carbon monoxide (CO), nitrogen dioxide (NO), ozone (O), and nitric oxide (NO) at a reference field site for one year. We developed calibration equations using randomly selected co-location subsets spanning 1 to 180 consecutive days out of the 1-year period and compared the potential root mean square errors (RMSE) and Pearson correlation coefficients (r). The co-located calibration period required to obtain consistent results varied by sensor type, and several factors increased the co-location duration required for accurate calibration, including the response of a sensor to environmental factors, such as temperature or relative humidity (RH), or cross-sensitivities to other pollutants. Using measurements from Baltimore, MD, where a broad range of environmental conditions may be observed over a given year, we found diminishing improvements in the median RMSE for calibration periods longer than about six weeks for all the sensors. The best performing calibration periods were the ones that contained a range of environmental conditions similar to those encountered during the evaluation period (i.e., all other days of the year not used in the calibration). With optimal, varying conditions it was possible to obtain an accurate calibration in as little as one week for all sensors, suggesting that co-location can be minimized if the period is strategically selected and monitored so that the calibration period is representative of the desired measurement setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10270383PMC
http://dx.doi.org/10.5194/amt-16-169-2023DOI Listing

Publication Analysis

Top Keywords

calibration periods
12
calibration period
12
calibration
11
low-cost sensors
8
calibration equations
8
accurate calibration
8
range environmental
8
environmental conditions
8
period
6
sensors
5

Similar Publications

XXXXX recently added brain to its fentanyl analog testing method for 14 analogs (fluoroisobutyryl fentanyl, acetyl fentanyl, acryl fentanyl, alfentanil, butyryl fentanyl, carfentanil, fentanyl, para-fluorofentanyl, furanyl fentanyl, methoxyacetyl fentanyl, norcarfentanil, norfentanyl, sufentanil, and valeryl fentanyl) and 3 U-series drugs (U-47700, U-48800, and U-49900). Brain is a protected and isolated organ with lower metabolic activity than other tissues, which can assist in interpreting results and preserving parent drug. Limited publications testing brain samples for fentanyl and fentanyl analogs exist and none describe homogenate stability for these analytes.

View Article and Find Full Text PDF

Objective: To critically appraise and synthesise existing risk prediction models for chemotherapy-induced oral mucositis (CIOM) in cancer patients, identifying their methodological strengths, limitations, and clinical utility to guide future model refinement.

Methods: Relevant literature on CIOM risk prediction models published in PubMed, Cochrane Library, Embase, Web of Science, CNKI, Wanfang Data Knowledge Service Platform, VIP, and CBM was searched, covering the period from the inception of the databases to May 9, 2025. Researchers independently screened the literature and extracted data, utilising the Prediction Model Risk Of Bias Assessment Tool (PROBAST) to evaluate the quality of the models.

View Article and Find Full Text PDF

Background: Conventional surveillance methods may miss healthcare-associated pathogen transmission, particularly for common, drug-susceptible organisms. It is unclear if prospective genomic analyses can help identify otherwise silent transmission events and inform prevention efforts.

Methods: We sequenced methicillin susceptible Staphylococcus aureus (MSSA) surveillance and clinical isolates in the neonatal intensive care unit (NICU) of an academic hospital between Feb 2022 and Mar 2024.

View Article and Find Full Text PDF

Electroencephalography-based brain-computer interfaces have revolutionized the integration of neural signals with technological systems, offering transformative solutions across neuroscience, biomedical engineering, and clinical practice. This review systematically analyzes advancements in electroencephalography-based brain-computer interface architectures, emphasizing four pillars, namely signal acquisition, paradigm design, decoding algorithms, and diverse applications. The aim is to bridge the gap between technology and application and guide future research.

View Article and Find Full Text PDF

Purpose: This study investigates factors associated with receiving return-to-work (RTW) coordination within primary healthcare and the association between received RTW coordination and the amount of sickness absence (SA) days.

Methods: This register study included 13019 people who had SA at some time between March 2019 and February 2020 and visited a primary healthcare clinic that employed a RTW coordinator. Logistic regressions were used to investigate received RTW coordination.

View Article and Find Full Text PDF