Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The shift from testing at centralized diagnostic laboratories to remote locations is being driven by the development of point-of-care (POC) instruments and represents a transformative moment in medicine. POC instruments address the need for rapid results that can inform faster therapeutic decisions and interventions. These instruments are especially valuable in the field, such as in an ambulance, or in remote and rural locations. The development of telehealth, enabled by advancements in digital technologies like smartphones and cloud computing, is also aiding in this evolution, allowing medical professionals to provide care remotely, potentially reducing healthcare costs and improving patient longevity. One notable POC device is the lateral flow immunoassay (LFIA), which played a major role in addressing the COVID-19 pandemic due to its ease of use, rapid analysis time, and low cost. However, LFIA tests exhibit relatively low analytical sensitivity and provide semi-quantitative information, indicating either a positive, negative, or inconclusive result, which can be attributed to its one-dimensional format. Immunoaffinity capillary electrophoresis (IACE), on the other hand, offers a two-dimensional format that includes an affinity-capture step of one or more matrix constituents followed by release and electrophoretic separation. The method provides greater analytical sensitivity, and quantitative information, thereby reducing the rate of false positives, false negatives, and inconclusive results. Combining LFIA and IACE technologies can thus provide an effective and economical solution for screening, confirming results, and monitoring patient progress, representing a key strategy in advancing diagnostics in healthcare.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2023.464109DOI Listing

Publication Analysis

Top Keywords

poc instruments
8
analytical sensitivity
8
advancements portable
4
instruments
4
portable instruments
4
instruments based
4
based affinity-capture-migration
4
affinity-capture-migration affinity-capture-separation
4
affinity-capture-separation clinical
4
clinical testing
4

Similar Publications

A directional self-priming continuous-driven compartmentalized microfluidic chip for multiplexed pathogen detection.

Analyst

September 2025

Research Centre for Analytical Instrumentation, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, P. R. China.

Rapid and efficient screening of foodborne pathogens is crucial for preventing bacterial spread and food poisoning. However, developing a multi-detection method that is easy to operate, offers good stability, and achieves high efficiency remains an enormous challenge. Existing multiplexed nucleic acid detection methods suffer from complex designs, leading to complicated operations, and non-robust sample introduction, causing primer/probe crosstalk and false-positive results.

View Article and Find Full Text PDF

Self-phosphorylating DNAzyme DK1 enables programmable multi-analyte readout via PfAgo.

Biosens Bioelectron

September 2025

Department of Biological Sciences, Faculty of Science, National University of Singapore, 117543, Singapore; Department of Biochemistry, Yong Loo Lin School of Medicine, National University of Singapore, 117597, Singapore; Precision Medicine Translational Research Programme (TRP), Yong Loo Lin School

DNAzymes possessing kinase-like activities have long held theoretical promise, yet their practical implementation has remained significantly limited. Notably, DNAzyme kinase 1 (DK1), discovered over two decades ago, exhibits a unique self-phosphorylation capability upon encountering specific substrates like ATP, but its broad-based and programmable applications have not yet been fully realized. In this study, we innovatively couple DK1's autophosphorylation mechanism with the PfAgo to establish a novel programmable cascade sensing platform named RASTEN (Robust pfAgo-based Strategy for POC Testing Non-nucleic Acid and Nucleic Acid).

View Article and Find Full Text PDF

Background: The increasing prevalence of methicillin-resistant Staphylococcus aureus (MRSA), particularly due to the presence of the mecA gene, emphasizes the need for decentralized, rapid, and accurate molecular diagnostics. While qPCR remains the gold standard method, its dependence on expensive equipment and centralized labs limits accessibility in field or point-of-care (POC) settings. To address this limitation, we developed an Electrochemical Loop-Mediated Isothermal Amplification (E-LAMP) platform for rapid, low-cost, and highly sensitive detection of the mecA gene, using 3D-printed electrodes and a smartphone-controlled potentiostat.

View Article and Find Full Text PDF

This study is aimed at evaluating the accuracy and feasibility of real-time continuous glucose monitoring (rt-CGM) in non-ICU hospitalized adult COVID-19 patients who had hyperglycemia requiring insulin therapy during admission. Medtronic Guardian Sensor 3 and transmitter were placed on the patient's abdomen. The patient performed a self-calibration of CGM via the application installed in the smartphone.

View Article and Find Full Text PDF

Patients with acute swollen joints are often presumed to have septic arthritis, leading to intravenous antibiotics and arthroscopic washout. Previously at our centre, joint fluid aspirates often lacked crystal analysis, resulting in excess culture-negative septic arthritis diagnoses. We developed a 'Hot Joint Pathway', hypothesising that since acute crystal arthropathy can be misdiagnosed as 'culture-negative septic arthritis', introducing the pathway would improve diagnostic accuracy.

View Article and Find Full Text PDF