Article Abstract

Purpose: The impact of cataracts on the measurement of macular choriocapillaris flow deficits (CC FDs) was assessed by comparing the quantitative results before and after cataract surgery using an image quality algorithm developed for swept-source optical coherence tomography angiography (SS-OCTA) scans and a validated strategy for quantifying the CC FDs.

Methods: SS-OCTA image quality scores and CC FDs measurements within the fovea-centered 1-mm, 3-mm, and 5-mm diameter circles were compared before and after cataract surgery. CC FDs changes in a modified Early Treatment Diabetic Retinopathy Study (ETDRS) grid were further investigated.

Results: Twenty-four eyes were studied. Overall image quality in all three circles was observed to improve significantly following the removal of cataracts (all P < 0.05). Although there was good repeatability in the measurements of CC FDs at both visits (intraclass correlation coefficients were over 0.95), significant decreases in CC FD measurements were observed after surgery within the 1-mm circle (P < 0.001) and the 3-mm circle (P = 0.011), but no changes were observed within the 5-mm circle (P = 0.509) or any of the quadrant sectors of the modified ETDRS grid (all P > 0.05).

Conclusions: The presence of cataracts resulted in worse image quality and increased CC FD measurements within the fovea-centered 1-mm and 3-mm circles, with the 1-mm circle being impacted the most.

Translational Relevance: The impaired detection of CC perfusion deficits within the central macula of cataract eyes needs to be appreciated when imaging the CC in phakic eyes, especially in clinical trials.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10266550PMC
http://dx.doi.org/10.1167/tvst.12.6.7DOI Listing

Publication Analysis

Top Keywords

image quality
16
impact cataracts
8
cataracts measurement
8
measurement macular
8
macular choriocapillaris
8
choriocapillaris flow
8
flow deficits
8
cataract surgery
8
measurements fovea-centered
8
fovea-centered 1-mm
8

Similar Publications

Purpose: In children with Langerhans Cell Histiocytosis (LCH), FDG-PET/CT is used for staging and response assessment. Whole-body MRI (WB-MRI) can serve as an ionizing radiation-free alternative for repeated whole-body imaging. The aim of this study was to compare WB-MRI with FDG-PET/CT for staging and response assessment in pediatric LCH.

View Article and Find Full Text PDF

Importance And Objective: Voice changes during menopause affect patients' communication and quality of life. This narrative review aims to provide a comprehensive exploration of voice changes during menopause. It presents objective and subjective/symptomatic changes as well as treatment options for this population.

View Article and Find Full Text PDF

Fetal 4D Flow CMR for Advanced Diagnostics of Congenital Heart Disease: A Prospective Cohort Study.

Eur Heart J Cardiovasc Imaging

September 2025

Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.

Aims: Fetal circulation undergoes complex changes in congenital heart disease (CHD) that are challenging to assess with fetal echocardiography. This study aimed to assess clinical feasibility and diagnostic value of 4D flow cardiac magnetic resonance (CMR) in fetal CHD.

Methods And Results: Pregnant women in advanced third trimester pregnancy with fetal CHD were prospectively recruited for fetal CMR between 08/2021 and 11/2024.

View Article and Find Full Text PDF

PurposeTo introduce, describe and validate a novel, 3D-printed portable slit lamp system integrated with a macro lens-equipped smartphone, providing clinicians with a quick, easy, and effective method for obtaining high-quality clinical images.Materials and MethodsA 3D-printed portable slit lamp was developed, comprising a warm white LED light pen housed in a custom case with a biconvex lens focusing light through a 0.4 mm slit.

View Article and Find Full Text PDF

Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality.

View Article and Find Full Text PDF