Transjugular intrahepatic portosystemic shunt creation (TIPS) in the angio-CT-a hybrid intervention with image fusion.

Eur Radiol

Department of Interventional Radiology, School of Medicine, University Hospital Klinikum Rechts Der Isar TUM, Technical University of Munich, Ismaninger Straße 22, 81675, Munich, Germany.

Published: November 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: For transjugular intrahepatic portosystemic shunt (TIPS) creation, ultrasound guidance for portal vein puncture is strongly recommended. However, outside regular hours of service, a skilled sonographer might be lacking. Hybrid intervention suites combine CT imaging with conventional angiography allowing to project 3D information into the conventional 2D imaging and further CT-fluoroscopic puncture of the portal vein. The purpose of this study was to assess whether TIPS using angio-CT facilitates the procedure for a single interventional radiologist.

Methods: All TIPS procedures from 2021 and 2022 which took place outside regular working hours were included (n = 20). Ten TIPS procedures were performed with just fluoroscopy guidance and ten procedures using angio-CT. For the angio-CT TIPS, a contrast-enhanced CT was performed on the angiography table. From the CT, a 3D volume was created using virtual rendering technique (VRT). The VRT was blended with the conventional angiography image onto the live monitor and used as guidance for the TIPS needle. Fluoroscopy time, area dose product, and interventional time were assessed.

Results: Hybrid intervention with angio-CT did lead to a significantly shorter fluoroscopy time and interventional time (p = 0.034 for both). Mean radiation exposure was significantly reduced, too (p = 0.04). Furthermore, the mortality rate was lower in patients who underwent the hybrid TIPS (0% vs 33%).

Conclusion: TIPS procedure in angio-CT performed by only one interventional radiologist is quicker and reduces radiation exposure for the interventionalist compared to mere fluoroscopy guidance. The results further indicate increased safety using angio-CT.

Clinical Relevance Statement: This study aimed to evaluate the feasibility of using angio-CT in TIPS procedures during non-standard working hours. Results indicated that the use of angio-CT significantly reduced fluoroscopy time, interventional time, and radiation exposure, while also leading to improved patient outcomes.

Key Points: • Image guiding such as ultrasound is recommended for transjugular intrahepatic portosystemic shunt creation but might be not available for emergency cases outside of regular working hours. • Transjugular intrahepatic portosystemic shunt creation using an angio-CT with image fusion is feasible for only one physician under emergency settings and results in lower radiation exposure and faster procedures. • Transjugular intrahepatic portosystemic shunt creation using an angio-CT with image fusion seems to be safer than using mere fluoroscopy guidance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10598145PMC
http://dx.doi.org/10.1007/s00330-023-09793-9DOI Listing

Publication Analysis

Top Keywords

transjugular intrahepatic
20
intrahepatic portosystemic
20
portosystemic shunt
20
shunt creation
16
radiation exposure
16
hybrid intervention
12
image fusion
12
tips procedures
12
working hours
12
fluoroscopy guidance
12

Similar Publications

Transjugular intrahepatic portosystemic shunt (TIPS) placement is a well-established intervention for portal hypertension. However, some patients experience persistent complications such as encephalopathy, ascites, or thrombocytopenia, especially when further TIPS optimization is not technically possible. Partial splenic embolization (PSE), typically performed for hypersplenism or certain hematologic conditions, can reduce portal venous inflow and improve cytopenias; however, its use as an adjunct to TIPS is less well described.

View Article and Find Full Text PDF

An Unusual Cause of Massive Per Vaginal Bleeding.

ACG Case Rep J

October 2024

Department of Gastroenterology and Hepatology, Singapore General Hospital, Singapore, Singapore.

Massive per vaginal bleeding from ectopic pelvic varices is an exceedingly rare presentation in patients with cirrhosis. A 60-year-old postmenopausal woman presented with massive per vaginal (PV) bleeding. Computerized tomography scan showed extensive portosystemic collaterals with a large collateral vessel from the splenic vein to the region of her previous caesarean scar, on a background of liver cirrhosis.

View Article and Find Full Text PDF

Introduction: The use of controlled-expansion transjugular intrahepatic portosystemic shunt (CX-TIPS) effectively controls portal hypertension (PH)-related complications while reducing risks related to fully expanded stents. We evaluated the effectiveness of CX-TIPS in a large Viennese patient cohort.

Method: We assessed the number of patients evaluated for CX-TIPS placement by interdisciplinary discussion at the Medical University of Vienna and included all patients from the prospective AUTIPS registry undergoing CX-TIPS placement between June 2018 - December 2024.

View Article and Find Full Text PDF

Transjugular intrahepatic portosystemic shunt (TIPS) is widely used to treat portal hypertension and its complications patients with cirrhosis. However, managing post-TIPS hepatic encephalopathy (HE) remains a major clinical challenge. HE is characterized by a high incidence and a complex pathogenesis, influenced by various factors.

View Article and Find Full Text PDF

Optimal guiding methods for transjugular intrahepatic portosystemic shunt creation: Characteristics of intravascular ultrasound other techniques.

World J Hepatol

August 2025

Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.

A recent study in examined the use of intravascular ultrasound (IVUS) for transjugular intrahepatic portosystemic shunt (TIPS) creation. The study concluded that IVUS significantly reduces procedure time, radiation exposure, and the number of needle passes compared to conventional fluoroscopic guidance. IVUS offers real-time visualization of the portal vein, but challenges remain in terms of equipment costs and the operator learning curve.

View Article and Find Full Text PDF