Background: Glycated hemoglobin A1c (HbA1c) is a critical index for the diagnosis and glycemic control evaluation of diabetes. However, a standardized method for HbA1c measurement is unaffordable and unavailable among the Chinese population in low-resource rural settings. Point-of-care (POC) HbA1c testing is convenient and inexpensive, but its performance remains to be elucidated.
Objective: To investigate the value of POC HbA1c for identifying diabetes and abnormal glucose regulation (AGR) in the resource-limited Chinese population.
Methods: Participants were recruited from 6 Township Health Centers in Hunan Province. Samples for POC HbA1c, venous HbA1c, fasting plasma glucose, and 2 h-plasma glucose were obtained after physical examination. The oral glucose tolerance test was performed as the gold standard for diagnosis. The diagnostic capacities of the POC HbA1c measurement in predicting undiagnosed diabetes and AGR were evaluated.
Results: Among 388 participants, 274 (70.6%) normoglycemic controls, 63 (16.2%) prediabetes patients, and 51 (13.1%) diabetes patients were identified with oral glucose tolerance test (OGTT). Meanwhile, among 97 participants who underwent two HbA1c detection methods simultaneously, a positive correlation was found between POC HbA1c and standardized HbA1c ( = 0.75, < 0.001). No notable systematic difference was observed from the Bland-Altman Plots. The POC HbA1c cutoff values were 5.95 and 5.25%, which efficiently identified diabetes (AUC 0.92) and AGR (AUC 0.89), respectively.
Conclusions: The alternative POC HbA1c test efficiently discriminated AGR and diabetes from normoglycemia, especially among the Chinese population in primary healthcare settings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10203162 | PMC |
http://dx.doi.org/10.3389/fpubh.2023.1078361 | DOI Listing |
Background And Aims: Glycated Hemoglobin (HbA1c) is crucial for diagnosing and monitoring diabetes. However, current tests are complex, invasive, costly, and often met with low compliance. This study aimed to find whether simple clinical, noninvasive measures of the ocular accommodation function may predict the glycated hemoglobin results in type-1 diabetes mellitus.
View Article and Find Full Text PDFJ Diabetes Res
September 2025
Department of Medicine, Mahidol University Faculty of Medicine Siriraj Hospital, Bangkok, Thailand.
This study is aimed at evaluating the accuracy and feasibility of real-time continuous glucose monitoring (rt-CGM) in non-ICU hospitalized adult COVID-19 patients who had hyperglycemia requiring insulin therapy during admission. Medtronic Guardian Sensor 3 and transmitter were placed on the patient's abdomen. The patient performed a self-calibration of CGM via the application installed in the smartphone.
View Article and Find Full Text PDFClin Chem
July 2025
Institute of Continuing Education, University of Cambridge, Cambridge, United Kingdom.
Background: Access to Hb A1c testing in low- and middle-income countries (LMICs) can be limited, especially in rural areas. This has led to an increased interest in the potential role of point-of-care testing (POCT) for Hb A1c. The analytical performance of many of these devices is poorly understood but accurate and precise measurement is essential for effective diabetes management.
View Article and Find Full Text PDFBMC Health Serv Res
May 2025
Department of Health Policy Planning and Management, Makerere University, P. O. Box 7072, New Mulago Hill Road, Mulago, Kampala, Uganda.
Introduction: Whereas fasting plasma glucose (FPG) is cheaper, the glycated haemoglobin (HBA1c) test, which does not require fasting, is more convenient for diabetes screening and could be available to patients throughout the day. In this study, we compared the cost effectiveness of the HBA1c test to that of the FPG test when used for point-of-care (POC) screening of type 2 diabetes in a low-resource setting in Uganda.
Methods: A cost-effectiveness analysis from a societal perspective was conducted for a single screening cycle of 1659 adults aged 35-70 years receiving care at the outpatient department of a general hospital.
Pediatr Diabetes
April 2025
Clinical Center for Intelligent Rehabilitation Research Shanghai YangZhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center) Tongji University School of Medicine Tongji University, Shanghai 201613, China.
Objective: Capillary glycated hemoglobin (HbA1c) may enhance screening for childhood prediabetes and diabetes, but variations in this parameter remain unclear. We aimed to develop percentiles of HbA1c and explore the influence of various variables on HbA1c level among Chinese children. .