Short dental implants with platform matching connection have been used for the rehabilitation of atrophic jaws whenever standard-length dental implants cannot be placed without prior bone augmentation. Yet, there remains a lack of data regarding the risk of technical failures when the all-on-4 configuration is performed in atrophic jaws with platform-switching distal short dental implants. Thus, the current study used the finite element method to evaluate the mechanical behavior at the level of the prosthetic components of the all-on-4 concept performed in atrophic mandible using short-length distal implants with platform switching (PSW) connection. Three models of the all-on-4 configuration were generated in human atrophic mandibles. The geometric models consisted of PSW connection tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) and straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants. A resultant force of 300 N was performed obliquely in the left side and posterior region of the prosthetic bar. The von Mises equivalent stress (σvm) and maximum and minimum principal stresses (σmax and σmin) were performed at level of the prosthetic components/implants and peri-implant bone crest, respectively. The general displacement of the models was also evaluated. The stress analysis was performed on the side of load application. The AO4S configuration showed the lowest values of σvm in the mesial left (ML) and distal left (DL) abutments (37.53 MPa and 232.77 MPa, respectively) and dental implants (91.53 MPa and 231.21 MPa, respectively). The AO4Sh configuration showed the highest values of σvm in the bar screw (102.36 MPa), abutment (117.56 MPa), and dental implant (293.73 MPa) of the ML area. Among the models, the highest values of σmax and σmin were noticed in the peri-implant bone crest of the AO4T design (131.48 MPa and 195.31 MPa, respectively). All models showed similar values of general displacements, which were concentrated in the mandible symphysis. The all-on-4 configurations designed with PSW connection and tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) or straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants were not associated with higher odds of technical failures. The AO4Sh design may be a promising option for the prosthetic rehabilitation of atrophic jaws.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1115/1.4062540 | DOI Listing |
ACS Biomater Sci Eng
September 2025
Materials Engineering, McGill university, Montreal H3A0C5, Canada.
Transcutaneous devices such as dental implants frequently fail due to infections at their interfaces with epithelial tissues. These infections are facilitated by the lack of integration between the devices and the surrounding soft tissues. This study aims to improve epithelial integration through surface modification of a transcutaneous implant material (polyetheretherketone (PEEK)).
View Article and Find Full Text PDFMinerva Dent Oral Sci
September 2025
Division of Implant Prosthodontics, Department of Surgical Sciences, University of Genoa, Genoa, Italy.
Background: The purpose of the study is to evaluate the use of a magnetodynamic instrument (Magnetic Mallet, Metaergonomica, Turbigo, Milan, Italy) to perform a horizontal bone expansion in edentulous sites that need to be rehabilitated with a dental implant.
Methods: A sample of 15 patients, 11 men and 4 women, age between 39 and 78 years, was analyzed. A total of 18 conical-shaped implants with a diameter of 3.
Cureus
August 2025
Department of Oral and Maxillofacial Surgery, University College of Medicine and Dentistry, The University of Lahore, Lahore, PAK.
Background And Aim: The incisive (nasopalatine) canal is an important anatomical structure of the anterior maxilla. It holds significance for surgeries and implant placement in the central incisor region. The size, shape, and relation with surrounding bones may vary by age, gender, and ethnicity.
View Article and Find Full Text PDFProg Mol Biol Transl Sci
September 2025
Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, QC, Canada. Electronic address:
This chapter, "Implantable Biosensors: Advancements and Applications," provides a succinct overview of the state-of-the-art in implantable biosensor technology, highlighting both established clinical uses and promising areas of ongoing research. It begins by outlining the fundamental principles and advantages of these sensors, such as their precision in physiological monitoring and capability for real-time therapeutic interventions. A variety of implantable sensors are categorized, including biophysical and biochemical types, each designed for specific medical applications.
View Article and Find Full Text PDFEur J Dent
September 2025
Clinical Sciences Department, College of Dentistry, Ajman University, Ajman, United Arab Emirates.
The implant impression technique plays a critical role in determining the accuracy of implant working casts. This laboratory study aimed to evaluate and compare the accuracy of working casts fabricated using four different impression techniques in both parallel and nonparallel implant configurations.An aluminum master model was made to simulate a mandibular dental arch.
View Article and Find Full Text PDF