98%
921
2 minutes
20
This study examined the reproducibility of GymAware, PUSH2 and Vmaxpro velocity monitoring devices during resistance training (RT). The sensitivity of these devices to detect the smallest changes in velocity that correspond to true changes in RT performance was also investigated. Fifty-one resistance-trained men and women performed an incremental loading (1RM) test, and two repetitions to failure tests with different loads, 72 h apart. During all repetitions, mean velocity (MV) and peak velocity (PV) were simultaneously recorded by two devices of each brand. Overall, GymAware was the most reliable and sensitive device for detecting the smallest changes in RT performance, regardless of the velocity metric used. Vmaxpro can be considered as an equivalent, cheaper alternative to GymAware for RT monitoring and prescription, but only if the MV metric is used. Caution should be exercised when using PUSH2 in practice due to their comparatively higher, unacceptable measurement error and generally low sensitivity to detect changes in RT performance. Collectively, these findings support the use of MV and PV from GymAware and MV from Vmaxpro devices for RT monitoring and prescription due to their low magnitudes of error; thus, allowing for the detection of meaningful changes in neuromuscular status and functional performance during RT.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10154341 | PMC |
http://dx.doi.org/10.1038/s41598-023-34416-0 | DOI Listing |
Alzheimers Res Ther
September 2025
Department of Neurology, Saarland University, Kirrberger Straße, 66421, Homburg/Saar, Germany.
Background: Alzheimer's disease (AD) patients and animal models exhibit an altered gut microbiome that is associated with pathological changes in the brain. Intestinal miRNA enters bacteria and regulates bacterial metabolism and proliferation. This study aimed to investigate whether the manipulation of miRNA could alter the gut microbiome and AD pathologies.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFFluids Barriers CNS
September 2025
Department of Medical Sciences, Neurology, Uppsala University, Uppsala, Sweden.
Background: Idiopathic normal pressure hydrocephalus (iNPH) predominantly manifests with gait disturbances, yet clinical assessments are vulnerable to confirmation bias, particularly post-shunt surgery. Blinded video evaluations are a method to enhance objectivity in gait assessment, but their reliability has never been systematically investigated. The aim was to evaluate the inter-rater reliability of blinded gait assessments in iNPH patients and to investigate how these assessments correlate with the Hellström iNPH scale and patient-reported health status following shunt surgery.
View Article and Find Full Text PDFMikrochim Acta
September 2025
Hunan Key Laboratory of Typical Environmental Pollution and Health Hazards, School of Public Health, Hengyang Medical School, University of South China, Hengyang, 421001, China.
An Ag-functionalized structural color hydrogel (Ag-SCH) sensor is constructed for colorimetric detection of glutathione (GSH). The hydrogel is prepared by using the coordination of Ag and 1-vinylimidazole (1-VI) as cross-linking network. GSH acts as a competitive ligand to break the coordination between Ag and 1-VI, leading to the expansion and structural color change of the hydrogel.
View Article and Find Full Text PDFSurg Endosc
September 2025
Department of Surgery and Cancer Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Introduction: This study aimed to evaluate surgeons' ergonomic satisfaction when using laparoscopic energy devices and to investigate how prolonged use affects muscle fatigue and surgical performance.
Methods: A two-part study, including a survey and a kinesiologic experiment, was conducted to compare 4 laparoscopic energy devices (D1-D4). Thirty surgeons completed a structured survey assessing ergonomic factors such as device weight, grip strength, handle design, comfort, and trigger location.