Article Abstract

Low-field (<1T) magnetic resonance imaging (MRI) scanners remain in widespread use in low- and middle-income countries (LMICs) and are commonly used for some applications in higher income countries e.g. for small child patients with obesity, claustrophobia, implants, or tattoos. However, low-field MR images commonly have lower resolution and poorer contrast than images from high field (1.5T, 3T, and above). Here, we present Image Quality Transfer (IQT) to enhance low-field structural MRI by estimating from a low-field image the image we would have obtained from the same subject at high field. Our approach uses (i) a stochastic low-field image simulator as the forward model to capture uncertainty and variation in the contrast of low-field images corresponding to a particular high-field image, and (ii) an anisotropic U-Net variant specifically designed for the IQT inverse problem. We evaluate the proposed algorithm both in simulation and using multi-contrast (T1-weighted, T2-weighted, and fluid attenuated inversion recovery (FLAIR)) clinical low-field MRI data from an LMIC hospital. We show the efficacy of IQT in improving contrast and resolution of low-field MR images. We demonstrate that IQT-enhanced images have potential for enhancing visualisation of anatomical structures and pathological lesions of clinical relevance from the perspective of radiologists. IQT is proved to have capability of boosting the diagnostic value of low-field MRI, especially in low-resource settings.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.media.2023.102807DOI Listing

Publication Analysis

Top Keywords

low-field magnetic
4
magnetic resonance
4
resonance image
4
image enhancement
4
enhancement stochastic
4
stochastic image
4
image quality
4
quality transfer
4
transfer low-field
4
low-field
2

Similar Publications

The unabating discovery of nanoskyrmions in centrosymmetric magnets challenges the conventional Dzyaloshinskii-Moriya (DM) skyrmion stabilization mechanism. We investigate Gd_{2}PdSi_{3} using polarized resonant x-ray scattering and find that the low-field incommensurate modulations are elliptical helices, evolving into spin-density waves at higher fields. Quasi-2D magnetism arises via local DM interactions generated by inversion symmetry breaking around Gd-Gd bonds, which we characterize using atomistic simulations.

View Article and Find Full Text PDF

A hybrid denoising method for low-field nuclear magnetic resonance data.

Magn Reson Lett

May 2025

State Key Laboratory of Petroleum Resources and Engineering, China University of Petroleum (Beijing), Beijing, 102249, China.

Low-field nuclear magnetic resonance (NMR) has broad application prospects in the exploration and development of unconventional oil and gas reservoirs. However, NMR instruments tend to acquire echo signals with relatively low signal-to-noise ratio (SNR), resulting in poor accuracy of spectrum inversion. It is crucial to preprocess the low SNR data with denoising methods before inversion.

View Article and Find Full Text PDF

Cardiovascular magnetic resonance imaging: Principles and advanced techniques.

Prog Nucl Magn Reson Spectrosc

September 2025

School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Institute for Biological and Medical

Cardiovascular magnetic resonance (CMR) imaging is an established non-invasive tool for the assessment of cardiovascular diseases, which are the leading cause of death globally. CMR provides dynamic and static multi-contrast and multi-parametric images, including cine for functional evaluation, contrast-enhanced imaging and parametric mapping for tissue characterization, and MR angiography for the assessment of the aortic, coronary and pulmonary circulation. However, clinical CMR imaging sequences still have some limitations such as the requirement for multiple breath-holds, incomplete spatial coverage, complex planning and acquisition, low scan efficiency and long scan times.

View Article and Find Full Text PDF

Background: Low-field MRI provides superior soft-tissue contrast compared to CT while costing significantly less than high-field MRI, which makes it a more accessible option for MRI-guided radiation therapy planning. Four-dimensional MRI (4D-MRI) is a technique that has been increasingly adopted clinically for internal target volume (ITV) delineation in free-breathing liver radiotherapy planning, and it requires high spatial resolution and accurate respiratory phase differentiation to enable precise dose planning. The feasibility of 4D-MRI at low-field strength, specifically at 0.

View Article and Find Full Text PDF

Low-field portable magnetic resonance imaging (pMRI) devices address a crucial requirement in the realm of healthcare by offering the capability for on-demand and timely access to MRI, especially in the context of routine stroke emergency. Nevertheless, images acquired by these devices often exhibit poor clarity and low resolution, resulting in their reduced potential to support precise diagnostic evaluations and lesion quantification. In this paper, we propose a 3D deep learning based model, named Stroke-Aware CycleGAN (SA-CycleGAN), to enhance the quality of low-field images for further improving diagnosis of routine stroke.

View Article and Find Full Text PDF