Article Abstract

Background: Machine perfusion has not been widely used because of its low demand in Japan; however, we believe its advantages may increase the number of organ transplants.

Methods: Here, we report the first clinical trial of machine perfusion for kidney transplantation in Japan. We used the CMP-X08 perfusion device (Chuo-Seiko Co, Ltd, Asahikawa, Hokkaido, Japan) to preserve the donated organs. The flow rate, perfusion pressure, renal resistance, and temperature were monitored during continuous hypothermic perfusion.

Results: From August 2020 to the present, 13 cases of perfusion-preserved kidney transplantation have been performed. Of these, ten and 3 cases were performed using organs donated after brain death (DBD) and cardiac death (DCD), respectively. The average age of the recipients was 55.9 ± 7.3 (45-66) years. The average dialysis period was 14.8 ± 8.4 (0-26) years. The donor's final creatinine level before organ retrieval was 1.58 ± 1.0 (0.46-3.07) mg/dL. The warm ischemic times of the 3 DCD donors were 3, 12, and 18 minutes. The average total ischemic time was 12.0 ± 3.7 (7.17-19.88) hours. The average MP time was 140 (60-240) minutes. A total of 7 cases had delayed graft function. The best creatinine level during hospitalization was 1.17 ± 0.43 (0.71-1.85) mg/dL. There were no primary non-functional cases, and perfusion preservation was safely performed in all cases.

Conclusions: Therefore, we present this report as the first clinical trial on machine perfusion for kidney transplantation from marginal donors with DBD and DCD in Japan.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.transproceed.2023.03.043DOI Listing

Publication Analysis

Top Keywords

machine perfusion
16
kidney transplantation
16
clinical trial
12
trial machine
12
perfusion preservation
8
transplantation japan
8
report clinical
8
perfusion kidney
8
creatinine level
8
perfusion
7

Similar Publications

Ischemia time is a well-established determinant of liver transplant outcomes. Patient survival is substantially affected by prolonged warm (WIT) and cold ischemia time (CIT) of the graft during liver transplant. One component that may be a contributing factor to both WIT and CIT is back bench time (BBT).

View Article and Find Full Text PDF

Objective: This study aims to construct a multimodal radiomics model based on contrast-enhanced ultrasound (CEUS) radiomic features, combined with conventional ultrasonography (US) images and clinical data, to evaluate its diagnostic efficacy in differentiating benign and malignant thyroid nodules (TNs) classified as C-TIRADS 4, and to assess the clinical application value of the model.

Methods: This retrospective study enrolled 135 patients with C-TIRADS 4 thyroid nodules who underwent concurrent US and CEUS before FNA/surgery. From each case, one US image and three CEUS key frames (2s post-perfusion, peak enhancement, 2s post-peak) were selected.

View Article and Find Full Text PDF

Extracellular vesicles (EVs) are small anuclear cellular membrane encapsulated fragments of importance for cellular interaction and transfer of information. These small vesicles, diverse in size and functionality, can be obtained from cells, tissues and bodily fluids. A complicated step for obtaining EVs from whole organs is understanding the optimal methodology for organ processing.

View Article and Find Full Text PDF

Machine perfusion is an emerging and transformative technology for dynamic organ preservation, assessment and repair. Whereas allografts continuously degrade during static cold storage, short-term perfusion can preserve high-quality organs for hours, enabling assessment, regional transport and improved logistics. Long-term perfusion for multiple days might extend the potential of clinical machine perfusion in the future, allowing for the assessment, reconditioning and repair of marginal or injured grafts for which more time is needed.

View Article and Find Full Text PDF

Purpose: Methods have been developed that apply image processing to 4-Dimension computed tomography (4DCT) to generate lung ventilation (4DCT-ventilation). Traditional methods for 4DCT-ventilation rely on density-change methods and lack reproducibility and do not provide 4DCT-perfusion data. Novel 4DCT-ventilation/perfusion methods have been developed that are robust and provide 4DCT-perfusion information.

View Article and Find Full Text PDF