Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We investigated the ability of echo-planar imaging with L1-regularized iterative sensitivity encoding-based diffusion-weighted imaging (DWI) to improve the image quality and reduce the scanning time in prostate magnetic resonance imaging. We retrospectively analyzed 109 cases of prostate magnetic resonance imaging. We compared variables in the quantitative and qualitative assessments among 3 imaging groups: conventional parallel imaging-based DWI (PI-DWI) with an acquisition time of 3 minutes 15 seconds; echo-planar imaging with L1-regularized iterative sensitivity encoding-based DWI (L1-DWI) with a normal acquisition time (L1-DWINEX12) of 3 minutes 15 seconds; and L1-DWI with a half acquisition time (L1-DWINEX6) of 1 minute 45 seconds. As a quantitative assessment, the signal-to-noise ratio (SNR) of DWI (SNR-DWI), the contrast-to-noise ratio (CNR) of DWI (CNR-DWI), and the CNR of apparent diffusion coefficient were measured. As a qualitative assessment, the image quality and visual detectability of prostate carcinoma were evaluated. In the quantitative analysis, L1-DWINEX12 showed significantly higher SNR-DWI than PI-DWI (P = .0058) and L1-DWINEX6 (P < .0001). In the qualitative analysis, the image quality score for L1-DWINEX12 was significantly higher than those of PI-DWI and L1-DWINEX6. A non-inferiority assessment demonstrated that L1-DWINEX6 was non-inferior to PI-DWI in terms of both quantitative CNR-DWI and qualitative grading of image quality with a <20% inferior margin. L1-DWI successfully demonstrated a reduced scanning time while maintaining good image quality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10146059PMC
http://dx.doi.org/10.1097/MD.0000000000033639DOI Listing

Publication Analysis

Top Keywords

image quality
16
imaging l1-regularized
12
l1-regularized iterative
12
iterative sensitivity
12
acquisition time
12
diffusion-weighted imaging
8
echo-planar imaging
8
sensitivity encoding-based
8
prostate magnetic
8
magnetic resonance
8

Similar Publications

Purpose: This study aimed to evaluate whether low-dose CT imaging using an Sn filter can provide image quality sufficient for the differential diagnosis of cranial deformities in infants while maintaining an effective dose comparable to that of conventional radiography.

Methods: We calculated the effective dose for both head X-ray imaging and low-dose CT with an Sn filter. Phantom images acquired using a CT scanner equipped with an Sn filter were evaluated for bone suture visibility at various conditions (from 10 mAs to 50 mAs, every 10 mAs) using a 4-point visual grading scale.

View Article and Find Full Text PDF

Purpose: This study presents the dose-based intra-preplan (DIP) method for intracavitary/interstitial brachytherapy (IC/ISBT) in cervical cancer, optimizing catheter configurations based on dose distribution. This study aimed to assess the DIP method's clinical feasibility and efficacy.

Methods And Materials: The DIP method incorporates the implant modeling function and the hybrid inverse planning optimization algorithm in Oncentra Brachy.

View Article and Find Full Text PDF

Genistein: A promising botanical fungicide candidate for enhancing tomato yield and quality by controlling Alternaria solani.

Pestic Biochem Physiol

November 2025

State Key Laboratory of Green Pesticides, Key Laboratory of Green Pesticide and Agricultural Bioengineering, Ministry of Education, Center for R&D of Fine Chemicals of Guizhou University, Guiyang 550025, China. Electronic address:

The overreliance on traditional chemical fungicides, combined with the emergence of resistance, poses significant challenges for food safety. Early blight, caused by the fungal pathogen Alternaria solani (A. solani), is among the most significant contributors to pre- and postharvest yield losses in tomato cultivation.

View Article and Find Full Text PDF

A ratiometric dual-channel fluorescent probe for selective Zn/Cd sensing: Applications in food quality control, real-time monitoring in living cells, and mice.

Anal Chim Acta

November 2025

State Key Laboratory of Materials-oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing, 211816, PR China; Zhangjiagang Institute of Nanjing Tech University, Suzhou, 215600, PR China. Electronic address:

Background: Zinc (Zn) and cadmium (Cd) ions are ubiquitous in industrial and daily life. Despite their critical impact on food safety and human health, current probes face significant limitations in simultaneously detecting both ions in complex food matrices.

Results: Herein, we successfully developed a pyrene-based FRET ratiometric fluorescent probe QP for the highly selective detection of Zn and Cd.

View Article and Find Full Text PDF

A FRET ratiometric fluorescent probe for detection of bisulfite in food: Insights into food quality and preservation.

Anal Chim Acta

November 2025

School of Materials Science and Engineering, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, China. Electronic address:

Background: Bisulfite (HSO) plays crucial roles in food safety and physiological health. In the food industry, sulfur dioxide (SO) and its derivative bisulfite (HSO) are extensively employed as preservatives and bleaching agents. Nonetheless, overconsumption of bisulfite can present health hazards like asthma and potentially cancer.

View Article and Find Full Text PDF