Background: Computed tomography (CT) and magnetic resonance imaging (MRI) are indicated for use in preoperative planning and may complicate diagnosis and place a burden on patients with lumbar disc herniation.
Purpose: To investigate the diagnostic potential of MRI-based synthetic CT with conventional CT in the diagnosis of lumbar disc herniation.
Material And Methods: After obtaining prior institutional review board approval, 19 patients who underwent conventional and synthetic CT imaging were enrolled in this prospective study. Synthetic CT images were generated from the MRI data using U-net. The two sets of images were compared and analyzed qualitatively by two musculoskeletal radiologists. The images were rated on a 4-point scale to determine their subjective quality. The agreement between the conventional and synthetic images for a diagnosis of lumbar disc herniation was determined independently using the kappa statistic. The diagnostic performances of conventional and synthetic CT images were evaluated for sensitivity, specificity, and accuracy, and the consensual results based on T2-weighted imaging were employed as the reference standard.
Results: The inter-reader and intra-reader agreement were almost moderate for all evaluated modalities (κ = 0.57-0.79 and 0.47-0.75, respectively). The sensitivity, specificity, and accuracy for detecting lumbar disc herniation were similar for synthetic and conventional CT images (synthetic vs. conventional, reader 1: sensitivity = 91% vs. 81%, specificity = 83% vs. 100%, accuracy = 87% vs. 91%; <0.001; reader 2: sensitivity = 84% vs. 81%, specificity = 85% vs. 98%, accuracy = 84% vs. 90%; 0.001).
Conclusion: Synthetic CT images can be used in the diagnostics of lumbar disc herniation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10798008 | PMC |
http://dx.doi.org/10.1177/02841851231169173 | DOI Listing |
J Neurosurg Case Lessons
September 2025
Department of Neurosurgery, University of Kentucky, Lexington, Kentucky.
Background: Single-position prone transpsoas lateral lumbar interbody fusion (PTP-LLIF) is an evolving minimally invasive surgery technique that merges the biomechanical and anatomical advantages of prone positioning with the LLIF approach. While PTP-LLIF enhances lumbar lordosis restoration and operative efficiency by eliminating patient repositioning, it presents unique ergonomic and visualization challenges for surgeons. This technical report describes a novel modification of the technique using the Teligen camera to improve intraoperative visualization and reduce surgeon fatigue.
View Article and Find Full Text PDFJ Vis Exp
August 2025
Tianjin Union Medical Center, The First Affiliated Hospital of Nankai University;
Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.
View Article and Find Full Text PDFN Am Spine Soc J
September 2025
Spine Institute of Connecticut at St. Francis Hospital, Hartford, CT, United States.
Background: The lateral transpsoas lumbar interbody fusion is associated with transient postoperative anterior thigh and inguinal dysesthesias and hip flexor weakness from manipulation of the psoas and interposed lumbar plexus. However, it remains unclear whether this translates to higher pain scores and opioid requirements.
Methods: Patients who had undergone one- or two-level extreme/direct (XLIF/DLIF), anterior (ALIF), or transforaminal lumbar interbody fusion (TLIF) between January 2018 and December 2023 for degenerative spinal pathology were included.
Cureus
September 2025
Orthopaedics Surgery, Hamad Medical Corporation, Doha, QAT.
Objectives The objective of this study is to report the initial surgical experience, challenges faced, and the preliminary outcomes of our cases. Materials and methods A retrospective analysis of the first 10 patients operated with TELD in our unit was performed. Ethical approval was obtained from the Hospital Review Committee of Hamad Medical Corporation.
View Article and Find Full Text PDFFront Physiol
August 2025
Department of Medical Research, Taichung Veterans General Hospital, Taichung, Taiwan.
Sciatica, often resulting from lumbar disc herniation or nerve compression, disrupts electrical signal transmission, leading to muscle atrophy, mitochondrial dysfunction, and impaired energy metabolism. This study explored the therapeutic effects of Fu's subcutaneous needling (FSN) in a chronic constriction injury (CCI) rat model, assessing its impact on neuropathic pain, muscle mass, and structural integrity. Histological and ultrastructural analyses demonstrated that FSN alleviated hypersensitivity, reduced muscle atrophy, preserved mitochondrial density, and maintained glycogen storage.
View Article and Find Full Text PDF