Article Abstract

Introduction: Prosthesis choice during aortic valve replacement (AVR) weighs lifelong anticoagulation with mechanical valves (M-AVR) against structural valve degeneration in bioprosthetic valves (B-AVR).

Methods: The Nationwide Readmissions Database was queried to identify patients who underwent isolated surgical AVR between January 1, 2016 and December 31, 2018, stratifying by prothesis type. Propensity score matching was used to compare risk-adjusted outcomes. Readmission at 1 y was estimated with Kaplan-Meier (KM) analysis.

Results: Patients (n = 109,744) who underwent AVR (90,574 B-AVR and 19,170 M-AVR) were included. B-AVR patients were older (median 68 versus 57 y; P < 0.001) and had more comorbidities (mean Elixhauser score: 11.8 versus 10.7; P < 0.001) compared to M-AVR patients. After matching (n = 36,951), there was no difference in age (58 versus 57 y; P = 0.6) and Elixhauser score (11.0 versus 10.8; P = 0.3). B-AVR patients had similar in-hospital mortality (2.3% versus 2.3%; P = 0.9) and cost (mean: $50,958 versus $51,200; P = 0.4) compared with M-AVR patients. However, B-AVR patients had shorter length of stay (8.3 versus 8.7 d; P < 0.001) and fewer readmissions at 30 d (10.3% versus 12.6%; P < 0.001) and 90 d (14.8% versus 17.8%; P < 0.001), and 1 y (P < 0.001, KM analysis). Patients undergoing B-AVR were less likely to be readmitted for bleeding or coagulopathy (5.7% versus 9.9%; P < 0.001) and effusions (9.1% versus 11.9%; P < 0.001).

Conclusions: B-AVR patients had similar early outcomes compared to M-AVR patients, but lower rates of readmission. Bleeding, coagulopathy, and effusions are drivers of excess readmissions in M-AVR patients. Readmission reduction strategies targeting bleeding and improved anticoagulation management are warranted in the first year following AVR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10131584PMC
http://dx.doi.org/10.1016/j.jss.2023.01.007DOI Listing

Publication Analysis

Top Keywords

aortic valve
8
valve replacement
8
readmissions surgical
4
surgical aortic
4
replacement influence
4
influence prosthesis
4
prosthesis type
4
type introduction
4
introduction prosthesis
4
prosthesis choice
4

Similar Publications

Background: Evidence informing clinical guidelines assumes that all transcatheter aortic valve implantation (TAVI) devices have similar effectiveness, in other words, displaying a class effect across TAVI valves. We aimed to assess the comparative effectiveness of different TAVI platforms relative to other TAVI counterparts or surgical aortic valve replacement (SAVR).

Methods: MEDLINE/Embase/CENTRAL were searched from inception until April 2025, for randomized controlled trials comparing outcomes with different commercially available TAVI devices relative to other TAVI counterparts or SAVR.

View Article and Find Full Text PDF

Standardising cardiac CT-based personalised surgical planning and execution in congenital aortic valvar disease.

Cardiol Young

September 2025

Congenital Valve Procedural Planning Program, Division of Pediatric Cardiac Surgery, Cleveland Clinic Children's, and Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA.

Background: Congenital aortic valvar disease represents a heterogeneous population with suboptimal surgical repair or replacement outcomes. We assess our approach and short-term outcomes in this population using cardiac CT evaluation for personalised surgical planning and execution.

Methods: We assessed patients who underwent aortic valvar surgery from February 2022 to August 2024.

View Article and Find Full Text PDF

Background: Asymmetric underexpansion of transcatheter heart valves (THVs), as observed on fluoroscopy, may influence prosthesis function or long-term durability of transcatheter aortic valve implantation (TAVI).

Aims: This study aimed to evaluate the effect of stent frame asymmetry on hemodynamic performance and clinical outcomes in ACURATE neo and neo2 THVs.

Methods: In a retrospective registry, the TAVI asymmetry index was defined as the ratio of the THV stent frame diameter.

View Article and Find Full Text PDF

Background: Routine preoperative echocardiograms (ECHOs) are frequently obtained in patients undergoing minimally invasive repair of pectus excavatum (MIRPE), but the benefit and necessity of preoperative screening remain debated. In this study, we sought to quantify the proportion of preoperative ECHOs that had clinically significant findings.

Methods: We conducted a retrospective review of 255 patients who underwent MIRPE at a single pediatric referral center from 2018 to 2023.

View Article and Find Full Text PDF

Objective: Societal guidelines recommend vitamin K antagonists (VKAs) for atrial fibrillation patients with recent biological valve implantation, but the safety and efficacy of direct oral anticoagulants (DOACs) in this setting remain uncertain, especially in the early postoperative period. This substudy of the Left Atrial Appendage Occlusion Study (LAAOS) III trial aimed to compare thromboembolic and bleeding outcomes in patients discharged on VKAs versus DOACs after bioprosthesis implantation or mitral valve repair.

Methods: A total of 2,645 patients were included, with 461 discharged on DOACs and 2184 on VKAs.

View Article and Find Full Text PDF