Article Abstract

Objectives: To explore a new method for electroencephalography (EEG) background analysis in neonates with hypoxic-ischemic encephalopathy (HIE) and its relationship with clinical grading and head magnetic resonance imaging (MRI) grading.

Methods: A retrospective analysis was performed for the video electroencephalography (vEEG) and amplitude-integrated electroencephalography (aEEG) monitoring data within 24 hours after birth of neonates diagnosed with HIE from January 2016 to August 2022. All items of EEG background analysis were enrolled into an assessment system and were scored according to severity to obtain the total EEG score. The correlations of total EEG score with total MRI score and total Sarnat score (TSS, used to evaluate clinical gradings) were analyzed by Spearman correlation analysis. The total EEG score was compared among the neonates with different clinical gradings and among the neonates with different head MRI gradings. The receiver operating characteristic (ROC) curve and the area under thecurve (AUC) were used to evaluate the value of total EEG score in diagnosing moderate/severe head MRI abnormalities and clinical moderate/severe HIE, which was then compared with the aEEG grading method.

Results: A total of 50 neonates with HIE were included. The total EEG score was positively correlated with the total head MRI score and TSS (=0.840 and 0.611 respectively, <0.001). There were significant differences in the total EEG score between different clinical grading groups and different head MRI grading groups (<0.05). The total EEG score and the aEEG grading method had an AUC of 0.936 and 0.617 respectively in judging moderate/severe head MRI abnormalities (<0.01) and an AUC of 0.887 and 0.796 respectively in judging clinical moderate/severe HIE (>0.05). The total EEG scores of ≤6 points, 7-13 points, and ≥14 points were defined as mild, moderate, and severe EEG abnormalities respectively, which had the best consistency with clinical grading and head MRI grading (<0.05).

Conclusions: The new EEG background scoring method can quantitatively reflect the severity of brain injury and can be used for the judgment of brain function in neonates with HIE.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9979395PMC
http://dx.doi.org/10.7499/j.issn.1008-8830.2208102DOI Listing

Publication Analysis

Top Keywords

total eeg
20
eeg score
20
background analysis
12
head mri
12
total
9
method electroencephalography
8
analysis neonates
8
neonates hypoxic-ischemic
8
eeg background
8
score
8

Similar Publications

Exploring the Arousal Intensity in Patients with Obstructive Sleep Apnea: Based on Odds Ratio Product.

Nat Sci Sleep

September 2025

Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, People's Republic of China.

Aim: Obstructive sleep apnea (OSA) is characterized by repetitive upper airway collapse during sleep, resulting in frequent cortical arousals. However, currently used frequency-based arousal metrics do not sufficiently capture the heterogeneity and clinical significance of arousal responses. The odds ratio product (ORP) is a novel electroencephalographic marker that provides a continuous assessment of sleep depth and has the potential to serve as an objective measure of arousal intensity.

View Article and Find Full Text PDF

Objective: This study combines a bibliometric analysis with an umbrella review to delineate the research landscape, hotspots, and emerging trends in the application of artificial intelligence to the clinical diagnosis and treatment of mild cognitive impairment.

Methods: We searched the Web of Science Core Collection for literature published between 2004 and 2024. Bibliometric analysis of the retrieved publications was performed using CiteSpace and VOSviewer to map publication trends, international collaboration networks, key contributors, and keyword co-occurrence.

View Article and Find Full Text PDF

Multi-modal virtual reality system for tinnitus treatment methods and validation.

PLoS One

September 2025

Department of Otorhinolaryngology-Head and Neck Surgery, Ansan Hospital, Korea University College of Medicine, Ansan, Republic of Korea.

Virtual reality (VR) has been utilized in clinical treatment because it can efficiently simulate situations that are difficult to control in the real world. In this study, we evaluated the efficacy of VR in patients with chronic subjective tinnitus. We assessed the clinical effectiveness based on electroencephalogram (EEG) analysis and questionnaire responses after patients participated in a 6-8-week VR-based tinnitus relief program.

View Article and Find Full Text PDF

Objective: Construct a predictive model for rehabilitation outcomes in ischemic stroke patients 3 months post-stroke using resting state functional magnetic resonance imaging (fMRI) images, as well as synchronized electroencephalography (EEG) and electromyography (EMG) time series data.

Methods: A total of 102 hemiplegic patients with ischemic stroke were recruited. Resting - state functional magnetic resonance imaging (fMRI) scans were carried out on all patients and 86 of them underwent simultaneous electroencephalogram (EEG) and electromyogram (EMG) examinations.

View Article and Find Full Text PDF