Distribution and removal mechanism of microplastics in urban wastewater plants systems via different processes.

Environ Pollut

Key Laboratory of Karst Geological Resources and Environment (Guizhou University), Ministry of Education, Guiyang, Guizhou 550000, China; College of Resources and Environmental Engineering, Guizhou University, Guiyang, Guizhou, 550000, China.

Published: March 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Microplastic pollution threatens water systems worldwide. As one of the most important parts of city wastewater treatment, wastewater treatment plants are not only microplastics interception barriers but also emission sources. Water samples were collected from each sewage treatment plant stage and sludge from the sludge dewatering room. Microplastics were extracted using wet peroxide oxidation and flotation, and the abundance, size, shape, and polymer type of microplastics were detected. Basis on the results, the influence of each process on the removal rate and characteristics of microplastics under the same influent source was analysed. The influent microplastic concentration in this study was 32.5 ± 1.0 n/L, which rapidly decreased after treatment. The removal rates of the sequencing batch reactor activated sludge, cyclic activated sludge, and anaerobic anoxic oxic technologies were 73.0%, 75.6%, and 83.9%, respectively. Most microplastics were transported to the sludge, and the concentration of microplastics in dehydrated sludge was 27.2 ± 3.1 n/g. Microplastics removal occurred primarily during the primary and secondary stages. Disposal processes, settling time, and process design affected wastewater treatment plant microplastic removal rates at each stage. Significant differences in microplastic characteristics were observed at each stage, with the most abundant being fragment shaped, particle sizes of 30-100 μm, and black in colour. Sixteen polymer types were identified using a Raman spectrometer. The predominant polymers are polypropylene, polyethylene, and polyethylene terephthalate. This study demonstrates that optimising the process design of existing wastewater treatment plants is crucial for the prevention and control of microplastic pollution. It is suggested that the process settings of contemporary wastewater treatment plants should be studied in depth to develop a scientific foundation for avoiding and managing microplastic pollution in urban areas.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.envpol.2023.121076DOI Listing

Publication Analysis

Top Keywords

wastewater treatment
20
microplastic pollution
12
treatment plants
12
microplastics
8
treatment plant
8
removal rates
8
activated sludge
8
process design
8
treatment
7
wastewater
6

Similar Publications

This study quantitatively evaluated the adsorption performance of natural bentonite for removing three dye classes-cationic (Basic dye: BEZACRYL RED GRL), anionic (Reactive dye: AVITERA LIGHT RED SE), and non-ionic (Disperse dye: BEMACRON BLUE HP3R) from synthetic textile wastewater. Batch adsorption experiments were conducted under varying conditions of contact time (15-90 min), adsorbent dosage (20-60 g L⁻), pH (4 and 12), and temperature (25-100 °C), with dye concentrations quantified by UV-Vis spectroscopy. At a contact time of 30 min and room temperature (25 °C), maximum removal efficiencies reached 99.

View Article and Find Full Text PDF

Cadmium (Cd) contamination in water poses a critical global challenge. A novel nanocomposite, montmorillonite (Mt)-supported nanoscale zero-valent iron (Mt-nZVI), synthesized by liquid phase reduction, offers a promising method for effectively removing Cd. The material underwent characterization through various techniques, including X-ray diffraction (XRD) and Scanning Electron Microscope(SEM).

View Article and Find Full Text PDF

Communities of plasmids as strategies for antimicrobial resistance gene survival in wastewater treatment plant effluent.

NPJ Antimicrob Resist

September 2025

Antimicrobial Resistance & Microbiome Research Group, Department of Biology, The Kathleen Lonsdale Institute for Human Health Research, Maynooth University, Maynooth, Co, Kildare, Ireland.

Plasmids facilitate antimicrobial resistance (AMR) gene spread via horizontal gene transfer, yet the mobility of genes in wastewater treatment plant (WWTP) resistomes remains unclear. We sequenced 173 circularised plasmids transferred from WWTP effluent into Escherichia coli and characterised their genetic content. Multiple multidrug-resistant plasmids were identified, with a significant number of mega-plasmids (>100 kb).

View Article and Find Full Text PDF

Lignin, a negatively charged, three-dimensional natural biopolymer, serves as an ideal support for metal catalysts due to its abundant functional groups and tunable chemical properties, which enable strong metal coordination and effective immobilization. Herein, we demonstrate a lignin-mediated Co/O co-doped AgS, symbolized as L-AgCoOS, bimetal oxysulfide catalyst via a facile hydrolysis method for the efficient reduction of toxic phenolic compounds (4-nitrophenol, 4-NP), organic dyes (methyl orange (MO), methylene blue (MB), rhodamine B (RhB), and heavy metal ions Cr(VI)) under dark conditions. Lignin, used to immobilize catalysts, also contributes to increasing the number of active catalytic sites and enhancing catalytic activity.

View Article and Find Full Text PDF

Decentralized wastewater management using treatment wetlands: Effective removal of antibiotics, resistance genes and organic micropollutants.

Sci Total Environ

September 2025

Department of Environmental Science, Aarhus University, Frederiksborgvej 399, 4000 Roskilde, Denmark; WATEC, Centre for Water Technology, Aarhus University, Ny Munkegade 120, 8000 Aarhus C, Denmark.

Treatment wetlands (TW) are a popular choice for decentralized wastewater treatment, with substantial documentation on their capacity to manage conventionally monitored pollutants. However, most insights into their effectiveness against emerging contaminants come from lab and mesocosm studies with a limited number of compounds, highlighting knowledge gaps in their performance at full scale. This study provides a first long-term, full-scale assessment of TW ability to remove a large number of organic micropollutants (OMPs) and manage antibiotic resistance under real-world conditions.

View Article and Find Full Text PDF