A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A completely digital workflow aided by cone beam computed tomography scanning to maintain jaw relationships for implant-supported fixed complete dentures: A clinical study. | LitMetric

A completely digital workflow aided by cone beam computed tomography scanning to maintain jaw relationships for implant-supported fixed complete dentures: A clinical study.

J Prosthet Dent

Professor, Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, PR China. Electronic address:

Published: January 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Statement Of Problem: The conventional workflow for the fabrication of implant-supported fixed complete dentures (IFCDs) is complex and makes it impossible to maintain jaw relationships. A fully digital workflow might solve this problem.

Purpose: The purpose of this clinical study was to develop a completely digital workflow aided by a cone beam computed tomography (CBCT) scan for the fabrication of IFCDs and to evaluate the accuracy of this workflow with regard to the maintenance of jaw relationships.

Material And Methods: All participants received a preoperative CBCT scan while wearing radiographic diagnosis dentures and occluding in the maximum intercuspal position. After the implant surgery, CBCT scanning, intraoral scanning, and stereophotogrammetry were performed to identify jaw anatomy, soft tissue, and the 3-dimensional (3D) locations of the implants, respectively. Then, all data were merged to transfer jaw relationships and generate digital casts to fabricate interim prostheses. A posttreatment CBCT scan was performed while the participants were wearing the interim prostheses and occluding in the maximum intercuspal position. The preoperative and postoperative jaw relationships were compared by CBCT cephalometric analysis. A meaningful and unacceptable difference was defined as 0.8 degrees and 2.4 degrees, respectively.

Results: Six participants (6 jaw relationships, 9 arches, and 58 implants) were included. All interim prostheses were stable and achieved symmetric occlusion after only minimal adjustment. A total of 18 angles were measured. Three angles revealed a meaningful minimal difference, and 1 angle revealed an unacceptable minimal difference. No prosthodontic complications were reported during the study.

Conclusions: A completely digital workflow for fabricating IFCDs achieved sufficient accuracy for the maintenance of jaw relationships throughout the treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2022.08.030DOI Listing

Publication Analysis

Top Keywords

jaw relationships
24
digital workflow
16
completely digital
12
cbct scan
12
interim prostheses
12
workflow aided
8
aided cone
8
cone beam
8
beam computed
8
computed tomography
8

Similar Publications