A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Physical Simulation of Ultrasonic Imaging Logging Response. | LitMetric

Physical Simulation of Ultrasonic Imaging Logging Response.

Sensors (Basel)

State Key Laboratory of Petroleum Resources and Prospecting, China University of Petroleum (Beijing), Beijing 102249, China.

Published: December 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Ultrasonic imaging logging can visually identify the location, shape, dip angle and orientation of fractures and holes. The method has not been effectively applied in the field; one of the prime reasons is that the results of physical simulation experiments are insufficient. The physical simulation of fracture and hole response in the laboratory can provide a reference for the identification and evaluation of the underground geological structure. In this work, ultrasonic scanning experiments are conducted on a grooved sandstone plate and a simulated borehole and the influence of different fractures and holes on ultrasonic pulse echo is studied. Experimental results show that the combination of ultrasonic echo amplitude imaging and arrival time imaging can be used to identify the fracture location, width, depth and orientation, along with accurately calculating the fracture dip angle. The evaluated fracture parameters are similar to those in the physical simulation model. The identification accuracy of the ultrasonic measurement is related to the diameter of the radiation beam of the ultrasonic transducer. A single fracture with width larger than or equal to the radiation beam diameter of the ultrasonic transducer and multiple fractures with spacing longer than or equal to the radiation beam diameter can be effectively identified.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9738145PMC
http://dx.doi.org/10.3390/s22239422DOI Listing

Publication Analysis

Top Keywords

physical simulation
16
radiation beam
12
ultrasonic
8
ultrasonic imaging
8
imaging logging
8
dip angle
8
fractures holes
8
ultrasonic transducer
8
equal radiation
8
beam diameter
8

Similar Publications