Background: With the number of older people living alone continuously rising, health-monitoring systems using information and communication technology (ICT) have been developed to manage their health issues. Life logging and human body communication sensor, types of ICT, have been adapted to manage and monitor health status of the elderly. However, its feasibility and efficacy remain unclear. This study aimed to examine the feasibility of TouchCare system which combined life logging with human body communication technology and its effect on the physical and psychological status of older adults living alone.
Methods: The TouchCare system, which consisted of a wearable watch, touchpad sensors, TouchCare application, and context-aware artificial intelligence, was developed by DNX Co. Ltd and used by the participants for 5 months. Out of the 111 selected participants, 91 replied to the satisfaction survey, and 22 participated in further investigation regarding their physical and psychological status. Finally, health assessment from 14 participants and sensor data from 13 participants (mean age = 77.4; SD = 3.8) were analyzed to compare their health status and health-related behaviors before and after use of the system.
Results: Out of the 91 participants who took the survey, 51.6% were satisfied with the system. Nutritional status (pre-intervention (10.6 ± 2.0) vs. post-intervention (11.8 ± 1.9), P = 0.04) and fall efficacy (pre-intervention (89.2 ± 15.3) vs. post-intervention (99.9 ± 0.5), P = 0.001) significantly improved after use of the system. Chronic pain (pre-intervention (4.8 ± 2.5) vs. post-intervention (4.4 ± 3.7), P = 0.78) and depressive symptoms (pre-intervention (5.7 ± 3.9) vs. post-intervention (5.4 ± 3.1), P = 0.60) reduced, while cognitive function (pre-intervention (4.1 ± 1.4) vs. post-intervention (4.6 ± 1.1), P = 0.15) and physical performance related to walking improved (pre-intervention (3.9 ± 0.2) vs. post-intervention (4.0 ± 0), P = 0.35), but were not significant. Behaviors related to physical activity and gait improved after use of the system; touch counts of refrigerator and microwave also increased with a decrease in night touch counts.
Conclusions: The TouchCare system was acceptable to older people living alone, and it efficiently managed their daily living while promoting their health-related behaviors. Further experimental studies are required to verify the effectiveness of the system, and to develop the system which meet the individualized needs of older people living alone.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9829959 | PMC |
http://dx.doi.org/10.1186/s12877-022-03482-w | DOI Listing |
PLoS One
August 2023
Service d'Endocrinologie, Diabétologie et Maladies Métaboliques, Centre Hospitalier Sud-Francilien de Corbeil-Essonnes, Corbeil-Essonnes, France.
Background: We assessed the performance and patient satisfaction of a new insulin patch pump, the A7+TouchCare (Medtrum), compared with the Omnipod system.
Methods: This multicenter, randomized, open-label, controlled study enrolled 100 adult patients with type 1 or type 2 diabetes mellitus (A1C ≥ 6.5% and ≤ 9.
BMC Geriatr
October 2022
College of Nursing, Mo-Im Kim Research Institute, Yonsei University, 50-1, Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Background: With the number of older people living alone continuously rising, health-monitoring systems using information and communication technology (ICT) have been developed to manage their health issues. Life logging and human body communication sensor, types of ICT, have been adapted to manage and monitor health status of the elderly. However, its feasibility and efficacy remain unclear.
View Article and Find Full Text PDFJ Diabetes Sci Technol
July 2023
Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Recent in vitro experiments with patch pumps (PP) Omnipod (OP), Omnipod DASH (OP-D), A6 TouchCare (A6), and Accu-Chek Solo (ACS) have observed periodic fluctuations in the delivered amount of insulin during basal rate and consecutive bolus delivery in some PP, calling for a more systematic characterization of these periodic delivery patterns. Here, it was found that during basal rate delivery of 1 U/h, some devices of OP, OP-D, and A6 showed deviations of up to ±30% from target delivery that consistently repeated every 5 hours, whereas ACS showed no clear periodicity with considerably lower deviations. Similar results were found during consecutive bolus delivery of 1 U, where deviations repeated consistently every five boluses in some devices of OP, OP-D, and A6.
View Article and Find Full Text PDFDiabetes Technol Ther
May 2021
Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Recently two new tubeless pumps for insulin therapy were introduced. They were tested for accuracy and occlusion detection and compared with the established patch pump Omnipod (OP). Using a modified setup for tubeless pumps based on IEC 60601-2-24, the basal rate and bolus delivery of the Accu-Chek Solo micropump system (ACS) and the A6 TouchCare System (A6) were measured with a microgravimetric method.
View Article and Find Full Text PDFJ Diabetes Investig
March 2018
Department of Endocrinology and Metabolism, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
Aims/introduction: The present study aimed to investigate the performance of a new real-time continuous glucose monitoring system.
Materials And Methods: Interstitial glucose levels were monitored for 7 days in 63 patients with type 1 or type 2 diabetes using the Medtrum A6 TouchCare CGM System. Venous blood was collected on a randomized day of the wear period.