Objective: We aim to leverage deep learning to develop a computer aided diagnosis (CAD) system toward helping radiologists in the diagnosis of follicular thyroid carcinoma (FTC) on thyroid ultrasonography.
Methods: A dataset of 1159 images, consisting of 351 images from 138 FTC patients and 808 images from 274 benign follicular-pattern nodule patients, was divided into a balanced and unbalanced dataset, and used to train and test the CAD system based on a transfer learning of a residual network. Six radiologists participated in the experiments to verify whether and how much the proposed CAD system helps to improve their performance.
Results: On the balanced dataset, the CAD system achieved 0.892 of area under the ROC (AUC). The accuracy, recall, precision, and F1-score of the CAD method were 84.66%, 84.66%, 84.77%, 84.65%, while those of the junior and senior radiologists were 56.82%, 56.82%, 56.95%, 56.62% and 64.20%, 64.20%, 64.35%, 64.11% respectively. With the help of CAD, the metrics of the junior and senior radiologists improved to 62.81%, 62.81%, 62.85%, 62.79% and 73.86%, 73.86%, 74.00%, 73.83%. The results almost repeated on the unbalanced dataset. The results show the proposed CAD approach can not only achieve better performance than radiologists, but also significantly improve the radiologists' diagnosis of FTC.
Conclusions: The performances of the CAD system indicate it is a reliable reference for preoperative diagnosis of FTC, and might assist the development of a fast, accessible screening method for FTC.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9709400 | PMC |
http://dx.doi.org/10.3389/fonc.2022.939418 | DOI Listing |
PLoS One
September 2025
School of Medical Engineering, Xinxiang Medical University, Xinxiang, China.
Computer-aided diagnostic (CAD) systems for color fundus images play a critical role in the early detection of fundus diseases, including diabetes, hypertension, and cerebrovascular disorders. Although deep learning has substantially advanced automatic segmentation techniques in this field, several challenges persist, such as limited labeled datasets, significant structural variations in blood vessels, and persistent dataset discrepancies, which continue to hinder progress. These challenges lead to inconsistent segmentation performance, particularly for small vessels and branch regions.
View Article and Find Full Text PDFArrhythm Electrophysiol Rev
August 2025
Department of Cardiology, National University Heart Centre Singapore Singapore.
Sudden cardiac death (SCD) is one of the leading causes of death worldwide. Coronary artery disease (CAD) is the predominant cause of SCD in older individuals, while inherited cardiomyopathies and channelopathies are more common in younger individuals under the age of 35 years. Genetic disorders associated with SCD have traditionally been perceived as monogenic disorders.
View Article and Find Full Text PDFEur J Pharm Biopharm
September 2025
Coriolis Pharma Research GmbH, Fraunhoferstraße 18 b, Martinsried 82152, Germany.
Fenton-like reagents serve as useful tools to induce oxidative stress in forced degradation studies of surfactants, providing a relevant model due to the possible presence of trace amounts of transition metal ions and peroxides in liquid drug formulations. It is known that catalytic reactivity of transition metal ions heavily depends on the ligands present in the solution and that it differs between buffer systems. Herein, we compare the influence of common buffers and chelating agents on poloxamer188 (P188) degradation by using a fast-gradient reversed phase chromatography with charged aerosol detection (LC-CAD) and automatic sample preparation.
View Article and Find Full Text PDFBr J Radiol
September 2025
Department of Radiology, Mayo Clinic, Rochester, MN, 55905, USA.
Objectives: Determine differences in quantitative stenosis severity measurements for ultra-high-resolution (UHR) photon-counting-detector (PCD) coronary CT angiography (cCTA) relative to energy-integrating-detector (EID) cCTA in a large patient cohort.
Methods: Adult participants seen between November 2022 and March 2023 underwent a clinical dual-source EID-CT cCTA and a research dual-source PCD-CT cCTA on the same day. Percent diameter stenosis (PDS) was measured, and stenosis severity was assigned based on the PDS of the most severe lesion per patient to determine a coronary-artery-disease reporting and data system (CAD-RADS) score.
J Esthet Restor Dent
September 2025
Department of Restorative Dentistry, Faculty of Dentistry, Istanbul University, Istanbul, Turkey.
Objective: To investigate the effect of deep margin elevation (DME) on the fracture resistance and fracture patterns of various indirect resin-based composite materials.
Materials And Methods: A total of 120 extracted maxillary premolars were prepared with standardized MOD onlay cavities extending 2 mm below the cementoenamel junction. Teeth were embedded in acrylic resin and randomly allocated into 10 groups (n = 12), including two controls (positive and negative) and two experimental groups with or without DME.