98%
921
2 minutes
20
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has undergone major improvements in recent years which have led to reduction of the analysis time, higher spatial resolution, and better sensitivity. However, quantification and accurate analysis remain one of the bottlenecks in LA-ICP-MS analysis and so far satisfactory calibration solutions are restricted to well-documented matrices and suitable internal standards. Additional uncertainties associated with laser fluence and beam size various ablation cells and interfaces make quantification even more challenging. This work is focused on the influence of fluence, beam size and aerosol transport on quantification in single pulse LA-ICP-MS analysis approaches based on pulse intensity, LA spot volumes, noise characteristics, . for different elements (As, Gd, La, Ni, Te and Zn), concentrations (between 10 and 1000 μg g), and matrices (gelatin standards and NIST SRM 612). The findings indicate that selection of the appropriate laser fluence, just above the ablation threshold, and beam size, depending on the interface of LA and ICP-MS, are critical for reliable quantification and should be properly adjusted to avoid excessive Poisson and Flicker noise, achieve maximum sensitivity, and prevent the formation of double peaks in single pulses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d2an01172g | DOI Listing |
Cureus
August 2025
Department of Oral and Maxillofacial Surgery, University College of Medicine and Dentistry, The University of Lahore, Lahore, PAK.
Background And Aim: The incisive (nasopalatine) canal is an important anatomical structure of the anterior maxilla. It holds significance for surgeries and implant placement in the central incisor region. The size, shape, and relation with surrounding bones may vary by age, gender, and ethnicity.
View Article and Find Full Text PDFInt J Oral Implantol (Berl)
September 2025
Purpose: To compare the accuracy of static guided surgery using a pilot drill guide and dynamic guided surgery for dental implant placement.
Materials And Methods: Partially edentulous adult patients requiring implant placement were randomly assigned to either the static guided surgery group using a pilot drill guide or the dynamic guided surgery group. Digital implant planning was conducted using intraoral scans and CBCT with planning software to determine the optimal prosthetic position.
Cureus
August 2025
Department of Pathology, Saint Savvas Anticancer Hospital of Athens, Athens, GRC.
Small cell neuroendocrine carcinoma of the cervix is an uncommon, aggressive tumor that most often affects women in their 40s and is frequently linked to high-risk human papillomavirus (HPV) infection. It is associated with poor prognosis even in early-stage disease. We report the case of a 36-year-old woman with high-risk HPV who presented with abnormal vaginal bleeding.
View Article and Find Full Text PDFAnal Chem
September 2025
Department of Chemistry, Southern University of Science and Technology, 518055 Shenzhen, China.
Electrochemiluminescence (ECL) imaging through closed bipolar nanoelectrode arrays (BPnEAs) has emerged as a promising method for in situ label-free wide-field electrochemical imaging. In this study, a cathodic ECL system based on [Ru(bpz)]/SO is combined with the BPnEAs fabricated on silicon nitride membrane windows through focused ion beam nanofabrication, enabling effective bipolar imaging of heterogeneous anodic electrocatalytic reactions. The shape, distribution, size, and material composition of individual electrodes within the array can be precisely controlled.
View Article and Find Full Text PDFAnal Chim Acta
November 2025
Marine Engineering College, Dalian Maritime University, Dalian, 116026, China. Electronic address:
On-site and accurately detecting, sizing and counting living algae are greatly needed under International Ballast Water Convention, yet still challenging due to the lack of miniatured device. In this paper, a miniatured microscope that has both blue view field and fluorescence field was developed. Dual-view-field with one exciting light is achieved by using a beam splitter to direct the light into two mini cameras.
View Article and Find Full Text PDF