Hand-eye calibration is an important step in controlling a vision-guided robot in applications like part assembly, bin picking and inspection operations etc. Many methods for estimating hand-eye transformations have been proposed in literature with varying degrees of complexity and accuracy. However, the success of a vision-guided application is highly impacted by the accuracy the hand-eye calibration of the vision system with the robot. The level of this accuracy depends on several factors such as rotation and translation noise, rotation and translation motion range that must be considered during calibration. Previous studies and benchmarking of the proposed algorithms have largely been focused on the combined effect of rotation and translation noise. This study provides insight on the impact of rotation and translation noise acting in isolation on the hand-eye calibration accuracy. This deviates from the most common method of assessing hand-eye calibration accuracy based on pose noise (combined rotation and translation noise). We also evaluated the impact of the robot motion range used during the hand-eye calibration operation which is rarely considered. We provide quantitative evaluation of our study using six commonly used algorithms from an implementation perspective. We comparatively analyse the performance of these algorithms through simulation case studies and experimental validation using the Universal Robot's UR5e physical robots. Our results show that these different algorithms perform differently when the noise conditions vary rather than following a general trend. For example, the simultaneous methods are more resistant to rotation noise, whereas the separate methods are better at dealing with translation noise. Additionally, while increasing the robot rotation motion span during calibration enhances the accuracy of the separate methods, it has a negative effect on the simultaneous methods. Conversely, increasing the translation motion range improves the accuracy of simultaneous methods but degrades the accuracy of the separate methods. These findings suggest that those conditions should be considered when benchmarking algorithms or performing a calibration process for enhanced accuracy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9581431 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0273261 | PLOS |
Sensors (Basel)
July 2025
College of Mechanical and Vehicle Engineering, Linyi University, Linyi 276012, China.
Large-sized components with numerous small key local features are essential in advanced manufacturing. Achieving high-precision quality control necessitates accurate and highly efficient three-dimensional (3D) measurement techniques. A flexible measurement system integrating a fringe-projection-based 3D scanner with an industrial robot is developed to enable the rapid measurement of large object surfaces.
View Article and Find Full Text PDFMicromachines (Basel)
July 2025
College of Electronic Information and Optical Engineering, Nankai University, Tianjin 300350, China.
To achieve robust and accurate collaborative 3D measurement under complex noise conditions, a global calibration method for dual-arm hand-eye systems and multi-view 3D imaging is proposed. A multi-view 3D scanning approach based on ICP (M3DHE-ICP) integrates a multi-frequency heterodyne coding phase solution with ICP optimization, effectively correcting stitching errors caused by robotic arm attitude drift. After correction, the average 3D imaging error is 0.
View Article and Find Full Text PDFMed Image Anal
October 2025
Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200241, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China.
The precise localization of small peripheral lung nodules (< 2 cm) poses a frequent challenge in clinical practice owing to the minimal invasion and low radiation dose requirements. The accuracy of lesion localization is often affected by the patient's respiratory movement during the localization process. In this study, an enhanced robot-assisted localization framework that integrates a novel motion compensation algorithm is proposed for radiation-free pulmonary nodule localization.
View Article and Find Full Text PDFProc Inst Mech Eng H
June 2025
School of Electromechanical Engineering, Guangdong University of Technology, Guangzhou, China.
Orthopedic surgical robot systems increasingly demand high-precision positioning and orientation. Low accuracy of positioning and orientation is a potential hazard during a surgery and also affects the surgical quality. The transformation relationship between the robot base coordinate system and the optical tracking system, which is called hand-eye calibration, is supposed to be calibrated accurately preoperatively.
View Article and Find Full Text PDFSensors (Basel)
May 2025
Intelligent Robotics Research Institute, Fudan Academy for Engineering and Technology, Fudan University, Shanghai 200433, China.
To optimize the structure and workflow of the 3D measurement robot system, reduce the dependence on specific calibration targets or high-precision calibration objects, and improve the versatility of the system's self-calibration, this paper proposes a robot hand-eye calibration algorithm based on irregular targets. By collecting the 3D structural information of an object in space at different positions, a random sampling consistency evaluation based on the fast point feature histogram (FPFH) is adopted, and the iterative closest point (ICP) registration algorithm with the introduction of a probability model and covariance optimization is combined to iteratively solve the spatial relationship between point clouds, and the hand-eye calibration equation group is constructed through spatial relationship analysis to solve the camera's hand-eye matrix. In the experiment, we use arbitrary objects as targets to execute the hand-eye calibration algorithm and verify the effectiveness of the method.
View Article and Find Full Text PDF