Importance: A bayesian network meta-analysis (NMA) can help compare the various types of multifocal and monofocal intraocular lenses (IOLs) used in clinical practice.

Objective: To compare outcomes of presbyopia-correcting IOLs frequently recommended in clinical practice through a bayesian NMA based on a systematic review.

Data Sources: Medline (PubMed) and the Cochrane Central Register of Controlled Trials (CENTRAL) were searched on May 15, 2021, from inception.

Study Selection: Based on the research question, randomized clinical trials assessing multifocal IOLs in patients who underwent bilateral cataract extraction were searched. Nonrandomized studies, studies in patients with unilateral or contralateral cataract extractions, duplicated studies, conference abstracts, and nonpeer-reviewed articles were excluded.

Data Extraction And Synthesis: Descriptive statistics and outcomes were extracted. The NMA was conducted to compare different types of IOLs. The mean differences for continuous variables, odds ratios for binary variables, 95% credible intervals (CrIs), and ranks of interventions were estimated.

Main Outcomes And Measures: The outcomes examined included binocular visual acuities by distance and optical quality, including glare, halos, and spectacle independence.

Results: This NMA included 27 studies comprising 2605 patients. For uncorrected near visual acuity, trifocal IOLs (mean difference, -0.32 [95% CrI, -0.46 to -0.19]) and old bifocal diffractive IOLs (mean difference, -0.33 [95% CrI, -0.50 to -0.14]) afforded better visual acuity than monofocal IOLs. Regarding uncorrected intermediate visual acuity, extended depth-of-focus IOLs provided better visual acuity than monofocal IOLs. However, there were no differences between extended depth-of-focus and trifocal diffractive IOLs in pairwise comparisons. For uncorrected distant visual acuity, all multifocal IOLs were comparable with monofocal IOLs. There were no statistical differences between multifocal and monofocal IOLs regarding contrast sensitivity, glare, or halos.

Conclusions And Relevance: For patients considering a multifocal IOL due to presbyopia, bilateral implantation of a trifocal IOL might be an optimal option for patients without compromising distant visual acuity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9501783PMC
http://dx.doi.org/10.1001/jamaophthalmol.2022.3667DOI Listing

Publication Analysis

Top Keywords

visual acuity
24
monofocal iols
16
iols
13
extended depth-of-focus
12
visual
8
optical quality
8
monofocal intraocular
8
intraocular lenses
8
bayesian network
8
network meta-analysis
8

Similar Publications

Purpose: To study the efficacy and safety of pro re nata regimen of brolucizumab, without loading dose, in treatment-naive patients with neovascular age-related macular degeneration (nAMD).

Case Series: Retrospective, observational study. We included all consecutive patients diagnosed with treatment- naïve nAMD undergoing Brolucizumab in Humanitas eye clinic, Turin, Italy between April 2022 and May 2023.

View Article and Find Full Text PDF

Purpose: To evaluate the time required for refractive error (RE) stabilization after standard phacoemulsification cataract surgery and identify preoperative factors influencing this duration.

Methods: This prospective case series study enrolled patients who had undergone phacoemulsification cataract surgery. RE stabilization was defined as 0.

View Article and Find Full Text PDF

Incision capsular bag herniation during subluxated lens surgery: mechanisms, management, and prevention.

Front Med (Lausanne)

August 2025

Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.

Purpose: To investigate the mechanism, intraoperative characteristics, management, and prevention of incision capsular bag herniation (ICBH), a previously unreported complication during cataract surgery in eyes with lens subluxation.

Methods: A retrospective observational case series was conducted on five male patients who developed ICBH during phacoemulsification with intraocular lens (IOL) implantation between January 2019 and December 2024. Among 867 subluxated-lens surgeries performed during this period, the estimated incidence of ICBH was 0.

View Article and Find Full Text PDF

Purpose: To compare postoperative astigmatism and visual acuity (VA) outcomes in patients undergoing penetrating keratoplasty (PK) using a liquid-interface femtosecond laser (LI-fs) trephination and a conventional vacuum-trephine (VT) technique.

Methods: Our single-center, retrospective data analysis included 121 eyes (121 patients) treated between April 2014 and November 2022. Patients received PK either with a LI-fs or a VT system.

View Article and Find Full Text PDF

Purpose: To report clinical outcomes in patients implanted with an isofocal optic-design intraocular lens (IOL) with double C-loop haptics following cataract surgery.

Methods: This was a multicentre-prospective-study involving 108 eyes (54 subjects) implanted with the Isopure Serenity (BVI, Inc). IOL.

View Article and Find Full Text PDF