Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: We investigate the performance of new hydrophobic diffractive multifocal intraocular lenses (IOL) with hydroxyethyl methacrylate (HEMA) and compare their optical quality, contrast sensitivity, and subjective photic phenomena.

Methods: Medical records of patients who underwent routine simple cataract surgery and insertion of an existing multifocal IOL (TFNT, TF group) or a new multifocal IOL (CNWT, CN group) were retrospectively reviewed. Clinical data was collected 2 months postoperatively and included optical quality analysis system (OQAS) indices, contrast sensitivity, and subjective degrees of photic phenomena.

Results: One hundred thirty-five eyes of 135 patients were included (CN group, 71; TF group, 64). There was no significant difference between the two groups in the visual acuity and defocus curve. The indices of OQAS did not show a significant difference between groups. Contrast sensitivity was significantly better in the CN group at all degrees, including the area under the log contrast sensitivity function (p = 0.01). The subjective photic phenomena survey showed better results for the CN group, with the proportion of patients reporting no photic phenomena as 9.9% and 3.1% in the CN and TF groups, respectively. The proportion of patients who reported severe photic phenomena was 11.3% in the CN group and 25.0% in the TF group. Although the follow-up period was only 2 months, glistening, surface scattering, and posterior capsule opacity were not observed in any patient.

Conclusions: The new multifocal IOL with HEMA is safe, and provides stable visual acuity as well as superior contrast sensitivity and lower subjective photic phenomena, over the prior IOL.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9494844PMC
http://dx.doi.org/10.1186/s12886-022-02600-xDOI Listing

Publication Analysis

Top Keywords

contrast sensitivity
24
photic phenomena
20
subjective photic
16
multifocal iol
12
multifocal intraocular
8
intraocular lenses
8
hydroxyethyl methacrylate
8
optical quality
8
sensitivity subjective
8
group
8

Similar Publications

Exhaled breath analysis offers noninvasive, early lung cancer detection via volatile organic compound (VOC) biomarkers, surpassing blood-based methods. Surface-enhanced Raman spectroscopy (SERS) is ideal for this purpose, combining molecular fingerprint specificity with single-molecule sensitivity. However, conventional SERS substrates face a fundamental limitation: while porous materials such as metal-organic frameworks effectively adsorb VOCs through their subnanometer pores (0.

View Article and Find Full Text PDF

Objective: To examine the association between visual impairment (VI) and (1) homebound status, (2) presence of home hazards, and (3) utilization of home-based long-term services and supports (LTSS) among older adults.

Design: Longitudinal and cross-sectional analyses using National Health and Aging Trends Study (NHATS) data (2021-2023).

Subjects: 3,022 Medicare beneficiaries aged ≥71 years (mean age 78.

View Article and Find Full Text PDF

Diagnostic Value of Centrally Restricted Diffusion in Differentiating Radiation Necrosis from Tumor Progression in Brain Metastases: A Single-Center Observational Study.

J Neuroradiol

September 2025

Department of Neuroradiology, East Group Hospital, Hospices Civils de Lyon. 59 Bd Pinel, 69500, Bron, France; CREATIS Laboratory, CNRS UMR 5220, INSERM U1294, Claude Bernard Lyon I University. 7 avenue Jean Capelle O, 69100, Villeurbanne, France. Electronic address:

Background: Distinguishing radiation necrosis (RN) from true progression (TP) in irradiated brain metastases is challenging. We evaluated the diagnostic performance of the centrally restricted diffusion sign on diffusion-weighted imaging (DWI).

Methods: From August 2014 to August 2024, we screened 321 patients with histologically confirmed brain metastases treated with radiation therapy and follow-up MRI for new or enlarging necrotic lesions ≥1 cm.

View Article and Find Full Text PDF

Solid lipid nanoparticles in imaging, diagnostics and theranostics: A review of a decade of innovations and clinical applications.

Colloids Surf B Biointerfaces

September 2025

Department of Pharmaceutical Sciences, Philadelphia College of Pharmacy, Saint Joseph's University, Philadelphia, PA 19104, USA. Electronic address:

The clinical demand for safer, more precise, and functionally versatile imaging tools has intensified with the increasing complexity of disease diagnosis and management. Despite major strides in imaging technologies such as MRI, CT, USG, and PET/SPECT, many modalities are grappled by issues including low specificity, high systemic toxicity of contrast agents, and limited ability to provide real-time functional data. Dreaded by these shortcomings, nanotechnology-based approaches such as liposomes, quantum dots (QDs), polymeric nanoparticles (NPs), gold NPs, lipid NPs, and metallic NPs have emerged as promising alternatives.

View Article and Find Full Text PDF

Introduction: Accurate diagnosis of subscapularis tears remains challenging due to the limitations of physical examinations and imaging techniques. Therefore, specific radiological parameters have been proposed as predictors of atraumatic subscapularis tears to improve diagnostic sensitivity and accuracy. These parameters include coracohumeral distance (CHD), coracoglenoid angle (CGA), coracoid angle (CA), coracoid overlap (CO), and coracohumeral angle (CHA).

View Article and Find Full Text PDF