Article Abstract

We present new results validating the capability of a high-fidelity computational simulator to accurately predict the responses of individual patients with acute respiratory distress syndrome to changes in mechanical ventilator settings. 26 pairs of data-points comprising arterial blood gasses collected before and after changes in inspiratory pressure, PEEP, FiO, and I:E ratio from six mechanically ventilated patients were used for this study. Parallelized global optimization algorithms running on a high-performance computing cluster were used to match the simulator to each initial data point. Mean absolute percentage errors between the simulator predicted values of PaO and PaCO and the patient data after changing ventilator parameters were 10.3% and 12.6%, respectively. Decreasing the complexity of the simulator by reducing the number of independent alveolar compartments reduced the accuracy of its predictions. Clinical Relevance- These results provide further evidence that our computational simulator can accurately reproduce patient responses to mechanical ventilation, highlighting its usefulness as a clinical research tool.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC48229.2022.9871182DOI Listing

Publication Analysis

Top Keywords

simulator accurately
12
patient responses
8
changes mechanical
8
mechanical ventilator
8
ventilator settings
8
computational simulator
8
simulator
6
computational cardiopulmonary
4
cardiopulmonary physiology
4
physiology simulator
4

Similar Publications

Transcranial alternating current stimulation (tACS) enables non-invasive modulation of brain activity, holding promise for cognitive research and clinical applications. However, it remains unclear how the spiking activity of cortical neurons is modulated by specific electric field (E-field) distributions. Here, we use a multi-scale computational framework that integrates an anatomically accurate head model with morphologically realistic neuron models to simulate the responses of layer 5 pyramidal cells (L5 PCs) to the E-fields generated by conventional M1-SO tACS.

View Article and Find Full Text PDF

Background: Colorectal cancer (CRC) remains one of the leading causes of cancer-related mortality worldwide. The tumor microenvironment (TME), particularly the interactions between endothelial cells and cancer-associated fibroblasts (CAFs), plays a pivotal role in promoting tumor growth, angiogenesis, oxidative stress, and therapy resistance. The HUVEC-fibroblast co-culture model closely mimics stromal-endothelial interactions observed in CRC, enabling mechanistic insights not achievable in monocultures.

View Article and Find Full Text PDF

Echolocating bats provide vital ecosystem services and can be monitored effectively using passive acoustic monitoring (PAM) techniques. Duty-cycle subsampling is widely used to collect PAM data at regular ON/OFF cycles to circumvent battery and storage capacity constraints for long-term monitoring. However, the impact of duty-cycle subsampling and potential detector errors on estimating bat activity has not been systematically investigated for bats.

View Article and Find Full Text PDF

High cost of clinical trials hinders further enhancement of comprehensive mechanical properties of bioresorbable scaffolds (BRS). Therefore, a multi-objective optimization method combining surrogate modeling and finite element simulation is proposed, based on the evaluation of stents with various auxetic structures and materials. The results demonstrated that re-entrant hexagon stent made of PLA (PLA-RH stent) was a more ideal candidate, with superior radial recoil and force.

View Article and Find Full Text PDF

Purpose: Neonatal mortality is a significant global health issue, particularly in low- and middle-income countries. This study aims to identify and understand the factors contributing to high neonatal mortality rates in the cities of Kerman and Bam, Iran, to develop effective strategies for improvement.

Design/methodology/approach: We employed systems dynamics to develop Causal Loop Diagrams that capture qualitative interactions among determinants of neonatal mortality.

View Article and Find Full Text PDF