Purpose: Our purpose was to validate and compare the performance of 4 organ dose reconstruction approaches for historical radiation treatment planning based on 2-dimensional radiographs.

Methods And Materials: We considered 10 patients with Wilms tumor with planning computed tomography images for whom we developed typical historic Wilms tumor radiation treatment plans, using anteroposterior and posteroanterior parallel-opposed 6 MV flank fields, normalized to 14.4 Gy. Two plans were created for each patient, with and without corner blocking. Regions of interest (lungs, heart, nipples, liver, spleen, contralateral kidney, and spinal cord) were delineated, and dose-volume metrics including organ mean and minimum dose (D and D) were computed as the reference baseline for comparison. Dosimetry for the 20 plans was then independently reconstructed using 4 different approaches. Three approaches involved surrogate anatomy, among which 2 used demographic-matching criteria for phantom selection/building, and 1 used machine learning. The fourth approach was also machine learning-based, but used no surrogate anatomies. Absolute differences in organ dose-volume metrics between the reconstructed and the reference values were calculated.

Results: For D and D (average and minimum point dose) all 4 dose reconstruction approaches performed within 10% of the prescribed dose (≤1.4 Gy). The machine learning-based approaches showed a slight advantage for several of the considered regions of interest. For D (maximum point dose), the absolute differences were much higher, that is, exceeding 14% (2 Gy), with the poorest agreement observed for near-beam and out-of-beam organs for all approaches.

Conclusions: The studied approaches give comparable dose reconstruction results, and the choice of approach for cohort dosimetry for late effects studies should still be largely driven by the available resources (data, time, expertise, and funding).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9429523PMC
http://dx.doi.org/10.1016/j.adro.2022.101015DOI Listing

Publication Analysis

Top Keywords

dose reconstruction
16
reconstruction approaches
12
wilms tumor
12
radiation treatment
12
dose
8
organ dose
8
tumor radiation
8
treatment plans
8
regions interest
8
dose-volume metrics
8

Similar Publications

Patients with inflammation-associated coronary artery disease (CAD) may exhibit rapid progression and require regular coronary imaging. To evaluate the diagnostic performance of spectral photon-counting detector (PCD) coronary CTA with reduced radiation and contrast media doses for detecting coronary stenosis and in-stent restenosis in patients with inflammation-associated CAD. This prospective study enrolled patients with inflammation-associated CAD from January 2023 to March 2024.

View Article and Find Full Text PDF

Reconstructing bone defects remains a significant challenge in clinical practice, driving the urgent need for advanced artificial grafts that simultaneously promote vascularization and osteogenesis. Addressing the critical trade-off between achieving high porosity/strength and effective bioactivity at safe ion doses, we incorporated strontium (Sr) into β-tricalcium phosphate (β-TCP) scaffolds with a triply periodic minimal surface (TPMS) structure using digital light processing (DLP)-based three-dimensional (3D) printing. Systematically screening Sr concentrations (0-10 mol%), we identified 10 mol% as optimal, leveraging the synergy between the biomimetic TPMS architecture, providing exceptional mechanical strength (up to 1.

View Article and Find Full Text PDF

Introduction/aims: Therapeutic electrical stimulation (ES) of repaired nerves has been demonstrated to improve muscle function. Previous studies applied ES to the proximal transected nerve end (P-ES) with benefits to the neuronal cell body. We investigated whether a single ES dose applied to the distal end (D-ES) or distal and proximal ends (DP-ES) prior to nerve repair provides benefits to neuromuscular junction (NMJ) and muscle recovery.

View Article and Find Full Text PDF

Background And Purpose: To date, no consensus guidelines have been published that systematically guide delineation of primary and nodal Clinical Target Volumes (CTVs) in patients who require post-operative radiotherapy (PORT) for mucosal Head and Neck squamous cell carcinoma (HNSCC). As a result, significant individual, institutional and national variation exists in the way that CTVs are delineated in the post-operative setting, leading to considerable heterogeneity in radiotherapy treatment.

Methods: A multi-disciplinary group of experts convened by the European Society for Radiotherapy and Oncology (ESTRO) set-out principles for the multi-disciplinary management of oral cavity squamous cell carcinoma (OCSCC).

View Article and Find Full Text PDF

Tire wear particles (TWP) represent a significant source of marine microplastic pollution and have been shown to pose a considerable threat to marine organisms. In this study, the marine rotifer Brachionus plicatilis was employed as a model organism to systematically assess the effects of micron-sized and nano-sized TWP, as well as their leachates, on rotifer behavior, and underlying molecular mechanisms. The results revealed that TWP exposure significantly reduced rotifer motility, evidenced by decreased swimming speed and acceleration.

View Article and Find Full Text PDF