Article Abstract

For breast cancer patients treated in the prone position with tangential fields, a diamond-shaped light field (DSLF) can be used to align with corresponding skin markers for image-guided radiation therapy (IGRT). This study evaluates and compares the benefits of different DSLF setups. Seventy-one patients who underwent daily tangential kilovoltage (kV) IGRT were categorized retrospectively into four groups: (1) DSLF field size (FS) = 10 × 10 cm , gantry angle = 90° (right breast)/270° (left breast), with the same isocenter as treatment tangential beams; (2) same as group 1, except DSLF FS = 4 × 4 cm ; (3) DSLF FS = 4 × 4-6 × 8 cm , gantry angle = tangential treatment beam, off-isocenter so that the DSLF was at the approximate breast center; and (4) No-DSLF. We compared their total setup time (including any DSLF/marker-based alignment and IGRT) and relative kV-based couch shift corrections. For groups 1-3, DSLF-only dose distributions (excluding kV-based correction) were simulated by reversely shifting the couch positions from the computed tomography plans, which were assumed equivalent to the delivered dose when both DSLF and IGRT were used. For patient groups 1-4, the average daily setup time was 2.6, 2.5, 5.0, and 8.3 min, respectively. Their mean and standard deviations of daily kV-based couch shifts were 0.64 ± 0.4, 0.68 ± 0.3, 0.8 ± 0.6, and 1.0 ± 0.6 cm. The average target dose changes after excluding kV-IGRT for groups 1-3 were-0.2%, -0.1%, and +0.4%, respectively, whereas DSLF-1 was most efficient in sparing heart and chest wall, DSLF-2 had lowest lung D ; and DSLF-3 maintained the highest target coverage at the cost of highest OAR dose. In general, the use of DSLF greatly reduces patient setup time and may result in smaller IGRT corrections. If IGRT is limited, different DSLF setups yield different target coverage and OAR dose sparing. Our findings will help DSLF setup optimization in the prone breast treatment setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680565PMC
http://dx.doi.org/10.1002/acm2.13772DOI Listing

Publication Analysis

Top Keywords

setup time
12
dslf
10
diamond-shaped light
8
prone breast
8
radiation therapy
8
dslf setups
8
kv-based couch
8
groups 1-3
8
target coverage
8
oar dose
8

Similar Publications

Background: Extended delays in non-elective surgeries have been associated with suboptimal outcomes. The SARS-CoV-2 pandemic forced healthcare systems to adapt their setups for unscheduled procedures, leading, in our institution, to a reorganization from a setup with two dedicated operating rooms (ORs) at a central facility without dedicated teams to a temporary one with both dedicated teams and ORs during lockdown phase. This study evaluates the impact of this transitions on the time to surgery considering unscheduled procedures.

View Article and Find Full Text PDF

Evaluating the Oncologic and Safety Outcomes of High-Dose Palliative Radiation Treatment with 30 Grays in Five Fractions.

Cureus

August 2025

Division of Radiation Oncology and Developmental Radiotherapeutics, BC Cancer - Vancouver, Vancouver, CAN.

Introduction In select tumor sites, symptom palliation and local control can be improved through delivering higher biological equivalent doses (BED) of radiotherapy. However, not all patients are suitable candidates for stereotactic body radiation therapy (SBRT). The 30 Grays in five fractions (30/5) regimen is a conformal, hypofractionated regimen that offers a higher BED compared to conventional palliative radiotherapy.

View Article and Find Full Text PDF

Background: Passenger rail drivers' physical behaviors contribute to individual, organizational and community risks. As work tasks are theorized to determine physical behaviors performed during work hours, there is a need to clarify how work tasks determine passenger rail drivers' physical behaviors to inform improved work design.

Aims: The aim of this study was to describe the physical behaviors of passenger train drivers across their work tasks and breaks, and explore what potential influences create variations in physical behaviors within tasks.

View Article and Find Full Text PDF

Background: Avenanthramides (AVAs) and Avenacosides (AVEs) are unique to oats (Avena Sativa) and may serve as biomarkers of oat intake. However, information regarding their validity as food intake biomarkers is missing. We aimed to investigate critical validation parameters such as half-lives, dose-response, matrix effects, relative bioavailability under single dose, and in relation to the abundance of Feacalibacterium prausnitzii, and under repeated dosing, to understand the potential applications of AVAs and AVEs as biomarkers of oat intake.

View Article and Find Full Text PDF

Thermal imaging for estimating melting point in cheese: A cost-effective alternative to rheology.

JDS Commun

September 2025

Dairy and Food Science Department, Midwest Dairy Foods Research Center, South Dakota State University, Brookings, SD 57007.

The melting characteristics of cheese play a pivotal role in determining functional performance in various applications. Measuring the meltability and melting point of cheese is a challenge and requires sophisticated equipment, a laboratory setup, and personnel training, and the cost can be prohibitive. Over the years, many tests have been developed to determine the meltability or melting point of cheese.

View Article and Find Full Text PDF