A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

AN INTER-COMPARISON OF PASSIVE DOSEMETERS FOR TERRESTRIAL GAMMA RADIATION MEASUREMENTS. | LitMetric

AN INTER-COMPARISON OF PASSIVE DOSEMETERS FOR TERRESTRIAL GAMMA RADIATION MEASUREMENTS.

Radiat Prot Dosimetry

Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China.

Published: September 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

To evaluate the measurement method of passive dosemeters for terrestrial gamma radiation measurements. An inter-comparison of passive dosemeters for terrestrial gamma radiation measurements was organized alternately by the Japan Chemical Analysis Center, National Institute for Radiological Protection of Chinese Center for Disease Control and Prevention and Radiation Monitoring Technical Center of Ministry of Environmental Protection every 2 years. The procedures and exposure conditions of the field-exposure and reference irradiation test were provided by the organizer. During 2019-2020, the En values of Field-1 and Field-2 in three laboratories were lower than 1.0 and assigned 'acceptable' according to inter-comparison criteria. After the correction of the fading effect of dosemeter material, the En values of reference irradiation test (0.301 mGy, 1.000 mGy) in three laboratories were lower than 1.0 and assigned 'acceptable'.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncac153DOI Listing

Publication Analysis

Top Keywords

passive dosemeters
12
dosemeters terrestrial
12
terrestrial gamma
12
gamma radiation
12
radiation measurements
12
inter-comparison passive
8
reference irradiation
8
irradiation test
8
three laboratories
8
laboratories lower
8

Similar Publications