Article Abstract

Background: The primary objective was to compare the accuracy of dynamic computed tomography (CT) angiography (d-CTA) with standardized triphasic contrast enhanced CT angiography (t-CTA) in diagnosing endoleak type after endovascular aortic repair (EVAR) using digital subtraction angiography (DSA) as reference standard. The secondary objective was to study the impact of d-CTA on image fusion-guided endoleak embolization.

Methods: A retrospective review of patients who underwent d-CTA imaging after EVAR between March 2019 and July 2021 was performed. Deidentified images were independently reviewed by two-two blinded readers to document endoleak type and target vessels. An impact of d-CTA-guided embolization was evaluated by a number of planning angiograms, radiation exposure, and accuracy of target vessel overlay.

Results: During the study period, 52 patients underwent d-CTA and 19 had all 3 modalities available for analysis. DSA imaging confirmed 4 (21.0%) type-I, 14 (73.7%) type-II, and 1 (5.3%) type-III endoleak. Findings from d-CTA matched with DSA in 19/19 cases (100%), whereas t-CTA matched in 14/19 cases (73.7%). In type-II endoleaks, the number of target vessels identified by d-CTA, t-CTA, and DSA were 23, 17, and 16, respectively. Mean dose-length product from d-CTA and t-CTA was 1,445 ± 551 and 1,612 ± 530 mGy × cm (P = 0.26). Nine patients underwent d-CTA-guided type-II endoleak embolization, using a median of 1 (range: 1-4) planning angiogram before embolization using 21.6 (± 8.7)% of total procedural radiation dose. Target vessel overlay was accurate in 9/9 (100%) cases.

Conclusions: Dynamic, time-resolved CTA is more accurate compared to standardized triphasic contrast enhanced CTA in diagnosing endoleak type after EVAR. In type-II endoleak, d-CTA better identified target vessels and enabled safe, targeted embolization.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.avsg.2022.06.014DOI Listing

Publication Analysis

Top Keywords

computed tomography
12
tomography angiography
12
endoleak type
12
patients underwent
12
target vessels
12
dynamic computed
8
targeted embolization
8
d-cta
8
standardized triphasic
8
triphasic contrast
8

Similar Publications

Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.

View Article and Find Full Text PDF

Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.

View Article and Find Full Text PDF

Aim: The purpose of this study was to assess the accuracy of a customized deep learning model based on CNN and U-Net for detecting and segmenting the second mesiobuccal canal (MB2) of maxillary first molar teeth on cone beam computed tomography (CBCT) scans.

Methodology: CBCT scans of 37 patients were imported into 3D slicer software to crop and segment the canals of the mesiobuccal (MB) root of the maxillary first molar. The annotated data were divided into two groups: 80% for training and validation and 20% for testing.

View Article and Find Full Text PDF

Evaluation of the usefulness of the masking on un-smoothed image method in Tl myocardial perfusion SPECT.

Radiol Phys Technol

September 2025

Department of Cardiovascular Internal Medicine, NHO Kagoshima Medical Center, 8-1, Shiroyamacho, Kagoshima, Kagoshima, 892-0853, Japan.

In Tl myocardial perfusion single-photon emission computed tomography (SPECT), gastric wall uptake can impact the inferior wall. This study aimed to evaluate the effectiveness and usefulness of the masking on un-smoothed image (MUS) method for Tl myocardial perfusion SPECT. A hemispherical gastric wall phantom was created to simulate the gastric fundus located closest to the myocardium, and the activity was enclosed to achieve an SPECT count ratio against the myocardium equivalent to that observed in clinical practice.

View Article and Find Full Text PDF

3D isotropic FastView MRI localizer allows reliable torsion measurements of the lower limb.

Eur Radiol Exp

September 2025

Department of Orthopaedics and Trauma Surgery, Orthopaedic Oncology, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.

Computed tomography (CT) and magnetic resonance imaging (MRI) are commonly used to assess femoral and tibial torsion. While CT offers high spatial resolution, it involves ionizing radiation. MRI avoids radiation but requires multiple sequences and extended acquisition time.

View Article and Find Full Text PDF