Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Importance: Fetal life and infancy might be critical periods for predisposing individuals to develop cardiovascular disease in adulthood.

Objective: To examine the associations of fetal and infant weight growth patterns with early markers of arterial health.

Design, Setting, And Participants: This population-based prospective cohort study was conducted from early fetal life onward among 4484 offspring of women in Rotterdam, the Netherlands, delivering between April 1, 2002, and January 31, 2006. Statistical analysis was performed between January 1 and August 31, 2021.

Exposures: Estimated fetal weight was measured in the second and third trimester. Data on weight and gestational age at birth were collected from midwives. Infant weight was measured at 6, 12, and 24 months.

Main Outcomes And Measures: The common carotid intima-media thickness (cIMT) and carotid distensibility were measured as early markers of arterial health.

Results: Follow-up measurements were available for 4484 children (2260 girls [50.4%]; median age, 9.7 years [95% range, 9.3-10.5 years]; and 2578 [57.5%] of Dutch ethnicity). Gestational age at birth was not associated with markers of arterial health. A 500-g-higher birth weight was associated with increased cIMT (standard deviation score [SDS], 0.08 mm [95% CI, 0.05-0.10 mm]) and a lower carotid distensibility (SDS, -0.05 × 10-3 kPa-1; [95% CI, -0.08 to -0.03 × 10-3 kPa-1]). Compared with children with a birth weight of 2500 to 4500 g, those weighing more than 4500 g had the lowest carotid distensibility (difference in SDS, -0.22 × 10-3 kPa-1 [95% CI, -0.42 to -0.02 × 10-3 kPa-1]). Conditional regression analyses showed that higher third-trimester fetal weight and birth weight were associated with increased cIMT (difference in SDS: third-trimester fetal weight, 0.08 mm [95% CI, 0.04-0.12 mm]; birth weight, 0.05 mm [95% CI, 0.01-0.09 mm]) and that higher weight at 6, 12, and 24 months was associated with increased cIMT (difference in SDS: 6 months, 0.05 mm [95% CI, 0.01-0.10 mm]; 12 months, 0.06 mm [95% CI, 0.02-0.10 mm]; and 24 months, 0.07 mm [95% CI, 0.03-0.11 mm]) and lower carotid distensibility (difference in SDS: 6 months, -0.04 × 10-3 kPa-1 [95% CI, -0.09 to -0.001 × 10-3 kPa-1]; 12 months, -0.05 × 10-3 kPa-1 [95% CI, -0.09 to -0.01 × 10-3 kPa-1]; and 24 months, -0.10 × 10-3 kPa-1 [95% CI, -0.15 to -0.06 × 10-3 kPa-1]). Compared with children with normal fetal and infant growth, children with normal fetal growth that was followed by accelerated infant growth had the highest cIMT (SDS, 0.19 mm [95% CI, 0.07-0.31 mm]) and lowest carotid distensibility (SDS, -0.16 × 10-3 kPa-1 [95% CI, -0.28 to -0.03 × 10-3 kPa-1]). The observed associations were largely explained by childhood body mass index.

Conclusions And Relevance: In this cohort study of 4484 children aged approximately 10 years, higher fetal and infant weight growth patterns were associated with early markers of impaired arterial health. Childhood body mass index seemed to be involved in the underlying pathways of the observed associations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9244605PMC
http://dx.doi.org/10.1001/jamanetworkopen.2022.19225DOI Listing

Publication Analysis

Top Keywords

kpa-1 [95%
24
carotid distensibility
20
fetal infant
16
early markers
16
markers arterial
16
birth weight
16
difference sds
16
[95%
14
infant growth
12
growth patterns
12

Similar Publications

Deep Learning-Assisted Organogel Pressure Sensor for Alphabet Recognition and Bio-Mechanical Motion Monitoring.

Nanomicro Lett

September 2025

Nanomaterials & System Lab, Major of Mechatronics Engineering, Faculty of Applied Energy System, Jeju National University, Jeju, 63243, Republic of Korea.

Wearable sensors integrated with deep learning techniques have the potential to revolutionize seamless human-machine interfaces for real-time health monitoring, clinical diagnosis, and robotic applications. Nevertheless, it remains a critical challenge to simultaneously achieve desirable mechanical and electrical performance along with biocompatibility, adhesion, self-healing, and environmental robustness with excellent sensing metrics. Herein, we report a multifunctional, anti-freezing, self-adhesive, and self-healable organogel pressure sensor composed of cobalt nanoparticle encapsulated nitrogen-doped carbon nanotubes (CoN CNT) embedded in a polyvinyl alcohol-gelatin (PVA/GLE) matrix.

View Article and Find Full Text PDF

Localized Gradient Conductivity Enabled Ultrasensitive Flexible Tactile Sensors with Ultrawide Linearity Range.

Adv Mater

September 2025

Key Laboratory of Low Dimensional Quantum Structures and Quantum Control of Ministry of Education, School of Physics and Electronics, Hunan Normal University, Changsha, 410081, China.

The high sensitivity and wide linearity are crucial for flexible tactile sensors in adapting to diverse application scenarios with high accuracy and reliability. However, conventional optimization strategies of constructing microstructures suffer from the mutual restriction between the high sensitivity and wide linearity. Herein, a novel design of localized gradient conductivity (LGC) with partly covered low-conductivity (low-σ) carbon/Polydimethylsiloxane layer on high-conductivity (high-σ) silver nanowires film upon the micro-dome structure is proposed.

View Article and Find Full Text PDF

Fresh walnuts are prone to moisture loss and spoilage after harvest, leading to reduced appearance and sensory quality. In this study, a multifunctional chitosan (CS)-based film was fabricated by incorporating a bacterial cellulose/oregano essential oil (BC/OEO) Pickering emulsion, with hydrogen bonding promoting cohesive matrix integration. The film's physicochemical properties, along with its antimicrobial and antioxidant activities, were systematically evaluated.

View Article and Find Full Text PDF

Strain-Insensitive, Crosstalk-Suppressed, Ultrawide-Linearity Iontronic Tactile Skin from a Synergistic Segment-Embedded Strategy.

ACS Sens

September 2025

The State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.

Tactile sensing arrays play a crucial role in human-machine interaction, robotics, and artificial intelligence by enabling the perception of physical stimuli on robotic surfaces or human skin. However, skin-attachable sensor arrays still suffer from strain interference and signal crosstalk under stretching or bending, particularly on curved or deformable surfaces. Here, we present a stretchable tactile array that is both strain-insensitive and crosstalk-suppressed, achieved via a hierarchically segmented design that mitigates lateral and vertical deformations synergistically.

View Article and Find Full Text PDF

Sensorineural hearing loss is the most common form of deafness, typically resulting from the loss of sensory cells on the basilar membrane, which cannot regenerate and thus lose sensitivity to sound vibrations. Here, we report a reconfigurable piezo-ionotropic polymer membrane engineered for biomimetic sustainable multi-resonance acoustic sensing, offering exceptional sensitivity (530 kPa) and broadband frequency discrimination (20 Hz to 3300 Hz) while remaining resistant to "dying". The acoustic sensing capability is driven by an ion hitching-in cage effect intrinsic to the ion gel combined with fluorinated polyurethane.

View Article and Find Full Text PDF