98%
921
2 minutes
20
Screening for chronic diseases, such as cancer, is an important public health priority, but traditionally only the frequency or rate of screening has received attention. In this work, we study the importance of adhering to recommended screening policies and develop new methodology to better optimize screening policies when adherence is imperfect. We consider a progressive disease model with four states (healthy, undetectable preclinical, detectable preclinical, clinical), and overlay this with a stochastic screening-behavior model using the theory of renewal processes that allows us to capture imperfect adherence to screening programs in a transparent way. We show that decreased adherence leads to reduced efficacy of screening programs, quantified here using elements of the lead time distribution (i.e., the time between screening diagnosis and when diagnosis would have occurred clinically in the absence of screening). Under the assumption of an inverse relationship between prescribed screening frequency and individual adherence, we show that the optimal screening frequency generally decreases with increasing levels of non-adherence. We apply this model to an example in breast cancer screening, demonstrating how accounting for imperfect adherence affects the recommended screening frequency.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10985-022-09563-7 | DOI Listing |
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFBMC Psychol
September 2025
Behavioral Epidemiology, Institute of Clinical Psychology and Psychotherapy, TUD Dresden University of Technology, Chemnitzer Straße 46, 01187, Dresden, Germany.
Background: Disruptive behavior and emotional problems - especially anxiety - are common in children and frequently co-occur. However, the role of co-occurring emotional problems in disruptive behavior intervention response is unclear. This study aimed to compare the effectiveness of an indicated prevention program in children with disruptive behavior problems with vs.
View Article and Find Full Text PDFHead Face Med
September 2025
Department of Oral and Maxillofacial Surgery, University Hospital Tübingen, Tübingen, Germany.
Background: The treatment of mandibular angle fractures remains controversial, particularly regarding the method of fixation. The primary aim of this study was to compare surgical outcomes following treatment with 1-plate versus 2-plate fixation across two oral and maxillofacial surgery clinics. The secondary aim was to evaluate associations between patient-, trauma-, and procedure-specific factors with postoperative complications and to identify high-risk patients for secondary osteosynthesis.
View Article and Find Full Text PDF