Unlabelled: AbstractObjective: To investigate the sample selection, result correction and clinical application value of multi nucleotide polymorphism chimerism detection method based on Next-generation sequencing.

Methods: The chimerism samples from November 2018 to June 2020 were collected, and Pearson correlation coefficient (r) was used to analyze the consistency of bone marrow and peripheral blood results detected by MNPseq; according to the different information integrity before transplantation, the calibration model was constructed to analyze the correction value of the micro chimerism results in each model; the clinical results were retrospectively analyzed to verify the reliability and practicability of chimerism results correction and the clinical value of MNPseq method.

Results: The results of bone marrow and peripheral blood chimerism detected by MNPseq method were consistent with each other and showed significant correlation (r=0.985, P<0.01). The three groups of calibration models were constructed according to different pre-transplant information. For the no donor and pre-transplant patients information group, the correction value was 1%; while for the group with pre-transplant patients and without donor information, 0.61% of the chimerism rate and 13 heterotopic points were used as the correction value; 0.26% of the chimerism rate and 21.57% of the heterotopic points were used as the correction value for the group with pre-transplantation patients and donor information. After correction, the number of the patients with incomplete chimerism decreased from 276 (74.19%) to 141 (37.91%) (P<0.01). Among 18 (18/141, 12.77%) patients with incomplete chimerism, the results of MNPseq in the patients were 25-39 days earlier than those in STR and flow MRD, and the result showed statistical significance.

Conclusion: MNPseq method can be used to monitor chimerism with peripheral blood instead of bone marrow samples, and the results can be corrected to detect the changes of graft status in vivo in a more timely manner.

Download full-text PDF

Source
http://dx.doi.org/10.19746/j.cnki.issn.1009-2137.2022.03.040DOI Listing

Publication Analysis

Top Keywords

nucleotide polymorphism
8
chimerism detection
8
correction clinical
8
bone marrow
8
marrow peripheral
8
peripheral blood
8
detected mnpseq
8
chimerism
6
[strategy optimization
4
clinical
4

Similar Publications

Asthma is a chronic respiratory disorder characterized by airway inflammation, hyperresponsiveness, and reversible airflow obstruction. Despite therapeutic strategies, asthma remains inadequately controlled in many patients. Genetic predisposition plays a significant role in asthma pathogenesis, and the Proteinase-Activated Receptor 2 (PAR-2), encoded by the F2RL1 gene, has been associated with asthma.

View Article and Find Full Text PDF

Low-cost and high-throughput RNA sequencing data for barley RILs achieved GP performance comparable to or better than traditional SNP array datasets when combined with parental whole-genome sequencing SNP data. The field of genomic selection (GS) is advancing rapidly on many fronts including the utilization of multi-omics datasets with the goal of increasing prediction ability and becoming an integral part of an increasing number of breeding programs ensuring future food security. In this study, we used RNA sequencing (RNA-Seq) data to perform genomic prediction (GP) on three related barley RIL populations.

View Article and Find Full Text PDF

Although several observational studies have suggested an association between plasma homocysteine (Hcy), vitamin B12, and folate levels and aortic diseases, including aortic dissection (AD), thoracic aortic aneurysm (TAA), and abdominal aortic aneurysm (AAA), the causality remains unclear. The aortic diameter was also included in the analysis. Therefore, this study employed Mendelian randomization (MR) analysis to investigate the effects of plasma Hcy, vitamin B12, and folate levels on aortic diseases.

View Article and Find Full Text PDF

Forensic applications of compound genetic markers: trends and future directions.

Sci Justice

September 2025

School of Life Sciences, University of KwaZulu-Natal, Private Bag X54001, Westville, Durban 4000, South Africa. Electronic address:

A compound marker integrates two or more genetic markers into a single assay. The application of compound markers enhances the predictive accuracy of genetic testing by leveraging the strengths of different genetic variations while mitigating the limitations of individual markers. Compound markers include SNP-SNPs, SNP-STRs, DIP-SNPs, DIP-STRs, Multi-In/Dels, CpG-SNPs, CpG-STRs/CpG-In/Del, and Methylation-Microhaplotypes.

View Article and Find Full Text PDF

Discriminatory power of the Precision ID GlobalFiler™ NGS STR panel v2 in monozygotic twins for forensic applications.

Sci Justice

September 2025

Departamento de Medicina Legal, Bioética, Medicina do Trabalho e Medicina Física e Reabilitação, Faculdade de Medicina FMUSP, Universidade de São Paulo, São Paulo, SP, Brazil. Electronic address:

Short Tandem Repeats (STRs) are the standard technique used in forensic genetics for individual identification due to their high polymorphism and robustness. Although Capillary Electrophoresis (CE) enables the analysis of many STRs, Next-Generation Sequencing (NGS) offers enhanced resolution and the ability to detect STRs' isoalleles and their flanking regions, enhancing the discrimination power of this analysis. Despite the fact that STR kits for NGS are well standardized for evaluating forensic samples, there is no data on their effectiveness in differentiating monozygotic (MZ) twins, which are indistinguishable by CE.

View Article and Find Full Text PDF