Article Abstract

Background: During open-door laminoplasty, the position of the bone gutter is not fixed, and when the gutter migrates inward, the outer end of the titanium plate must be fixed on the lamina edge. It is unclear whether this will affect the clinical efficacy. This study aimed to observe the influence of the titanium plate fixation position on the effectiveness of open-door laminoplasty for cervical spondylotic myelopathy (CSM).

Methods: A total of 98 patients with CSM who underwent open-door laminoplasty from August 2016 to October 2019 were included in this retrospective study. Fifty-five patients had the titanium plate fixed on the lateral mass (lateral mass group), and 43 patients had the titanium plate fixed on the lamina edge (lamina group). The opening angle, opening width, occurrence of hinge fracture, spinal cord drift distance, cervical curvature index (CCI), neurological function recovery (JOA score), neck function (NDI), C5 palsy and severity of axial symptoms were observed and compared between the two groups.

Results: The opening angle in the lamina group was significantly larger than that in the lateral mass group, while the opening width and the spinal cord drift distance were significantly smaller than those in the lateral mass group (P < 0.05). The occurrence of hinge fracture in the lamina group was significantly higher than that in the lateral group (25.6% and 9.1%, respectively) (P < 0.05). The CCI was maintained well in both groups (P > 0.05), and there was no significant difference between the groups (P > 0.05). After surgery, the JOA score significantly increased in both groups (P < 0.05), and the neurological recovery rates were similar between the two groups (62.6% vs. 64.5%). The NDI score significantly decreased in both groups (P < 0.05), but the lateral mass group recovered to a greater degree than the lamina group (P < 0.05). The occurrence of C5 palsy was 2.3% in the lamina group and 14.5% in the lateral mass group, and there was a significant difference between the groups (P < 0.05). Postoperative axial symptom severity was significantly worse in the lamina group than in the lateral mass group (P < 0.05).

Conclusions: In open-door laminoplasty, it is feasible to fix the titanium plate on the lateral mass or to the lamina due to the same neurological function recovery. However, fixing it to the lamina will increase the opening angle and decrease the opening width, making the hinge prone to fracture and increasing the severity of postoperative axial symptoms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9166363PMC
http://dx.doi.org/10.1186/s13018-022-03188-0DOI Listing

Publication Analysis

Top Keywords

titanium plate
20
lateral mass
16
open-door laminoplasty
12
plate fixed
12
mass group
12
position effectiveness
8
effectiveness open-door
8
laminoplasty cervical
8
cervical spondylotic
8
spondylotic myelopathy
8

Similar Publications

Finite Element Analysis of Mandibular Distraction Osteogenesis With a New Partially Bioabsorbable Distractor.

J Craniofac Surg

September 2025

Department of Craniomaxillofacial Surgery, Peking Union Medical College, Chinese Academy of Medical Sciences, Plastic Surgery Hospital, Beijing, China.

Objective: We designed a new distractor pairing a bioabsorbable upper fixing plate fixed by bioabsorbable screws with a traditional titanium distractor to simplify the second surgery removing the distractor after mandibular distraction osteogenesis. The present study aims to evaluate its biomechanical properties using finite element method.

Materials And Methods: Ten computer-aided designed models simulating mandibles of 5 patients under 2 working conditions, the instance of distraction and mastication, were produced.

View Article and Find Full Text PDF

Study of a near-cortical over-drilling technique on plate constructs with a conical locking system in a rabbit femoral fracture using a finite element model.

Med Eng Phys

October 2025

Centre for Simulation in Bioengineering, Biomechanics and Biomaterials (CS3B), Department of Mechanical Engineering, School of Engineering of Bauru, São Paulo State University (UNESP), Bauru, São Paulo, Brazil. Electronic address:

This study aimed to evaluate the near-cortical over-drilling technique on the mechanical behaviour of bone-plate constructs in a rabbit transverse femoral fracture. In vitro biomechanical testing and finite element (FE) models were used for analyses. Rabbits' bones (n = 14) were divided into two groups: G1 - without near-cortical over-drilling, and G2 - with near-cortical over-drilling.

View Article and Find Full Text PDF

Comparative clinical efficacy of nickel-titanium shape memory staples versus miniplate for Bartoníček-Rammelt type III and IV posterior malleolar fractures. A retrospective analysis of 47 consecutive patients treated between January 2022 and June 2024 documented operative time, intraoperative blood loss, fluoroscopy times, healing time, complications, postoperative fracture gap distance (mm), and articular surface step-off (mm) at the ankle joint. Ankle function was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, the Manchester-Oxford Foot Questionnaire (MOXFQ), and range of motion measurements at 3, 6, 12, and 14 months.

View Article and Find Full Text PDF

Segmental mandibulectomy is a valid treatment for advanced medication-related osteonecrosis of the jaw (MRONJ), but subsequent reconstruction is challenging. Spontaneous bone regeneration (SBR) following resection is exceedingly rare, particularly in the elderly. We present the case of a 63-year-old woman with stage 3 MRONJ who underwent a 60 mm segmental mandibulectomy.

View Article and Find Full Text PDF

Background/objective: Plate failure, including bending, is a critical issue in orthopedic fracture fixation, with clinical failure rates of 3.5%-19%, burdening patients and healthcare systems. Preclinical ovine models have observed similar plate bending due to overloading.

View Article and Find Full Text PDF