Determination of Transdermal Rate of Metallic Microneedle Array through an Impedance Measurements-Based Numerical Check Screening Algorithm.

Micromachines (Basel)

School of Electronics and Information Technology, State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-Sen University, Guangzhou 510006, China.

Published: April 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Microneedle systems have been widely used in health monitoring, painless drug delivery, and medical cosmetology. Although many studies on microneedle materials, structures, and applications have been conducted, the applications of microneedles often suffered from issues of inconsistent penetration rates due to the complication of skin-microneedle interface. In this study, we demonstrated a methodology of determination of transdermal rate of metallic microneedle array through impedance measurements-based numerical check screening algorithm. Metallic sheet microneedle array sensors with different sizes were fabricated to evaluate different transdermal rates. In vitro sensing of hydrogen peroxide confirmed the effect of transdermal rate on the sensing outcomes. An FEM simulation model of a microneedle array revealed the monotonous relation between the transdermal state and test current. Accordingly, two methods were primely derived to calculate the transdermal rate from the test current. First, an exact logic method provided the number of unpenetrated tips per sheet, but it required more rigorous testing results. Second, a fuzzy logic method provided an approximate transdermal rate on adjacent areas, being more applicable and robust to errors. Real-time transdermal rate estimation may be essential for improving the performance of microneedle systems, and this study provides various fundaments toward that goal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9146767PMC
http://dx.doi.org/10.3390/mi13050718DOI Listing

Publication Analysis

Top Keywords

transdermal rate
24
microneedle array
16
determination transdermal
8
rate metallic
8
metallic microneedle
8
array impedance
8
impedance measurements-based
8
measurements-based numerical
8
numerical check
8
check screening
8

Similar Publications

Purpose: The primary objective was to investigate the trends in orbital exenteration rates at a large tertiary care center, particularly in the context of recent advancements in immunotherapy, targeted agents, and globe-sparing surgical techniques, which have significantly impacted patient management.

Methods: We conducted a retrospective cohort study at the University of Miami. Patients who underwent orbital exenterations from 2011 to 2024 were identified by obtaining surgical coding data via institutional data brokers and validated through a rigorous surgical chart review.

View Article and Find Full Text PDF

Background: Hypertrophic scarring is a common pathological condition often associated with significant clinical symptoms. In pediatric patients, it can impair function and is difficult to treat due to the limited availability of effective treatment options.

Objective: To investigate the efficacy of pulsed dye and fractional CO laser combined with ultrasound-assisted transdermal drug delivery technology in the treatment of hypertrophic scars in pediatric patients.

View Article and Find Full Text PDF

Objective: To evaluate the clinical efficacy and safety of a novel skin wound dressing in promoting the repair of the ulcer wound after the treatment of Extramammary Paget's Disease (EMPD) with Hematoporphyrin Derivative Photodynamic Therapy (HpD-PDT).

Method: A total of 10 patients with EMPD previously treated with HpD-PDT were recruited to conduct a self semi-lesion controlled study on the treatment of conformal dressing to evaluate the efficacy and safety of the skin ulcer wound repair therapy after HpD-PDT. The skin lesions treated with novel HVHA Shutai dressing were the study intervention group, and the skin lesions treated with standard of care were the control group.

View Article and Find Full Text PDF

Cross-Reactive NSAID Hypersensitivity: Clinical Findings From Aspirin Provocation and Alternative Drug Challenge Testing.

Clin Transl Sci

September 2025

Division of Allergy, Asthma and Clinical Immunology, Department of Internal Medicine, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, South Korea.

Nonsteroidal anti-inflammatory drug (NSAID) hypersensitivity reactions are commonly reported but often overestimated due to reliance on clinical history alone. Accurate diagnosis and identification of safe alternative medications are essential for appropriate management. This retrospective study aimed to evaluate the clinical manifestations of NSAID hypersensitivity, assess the diagnostic value and safety of aspirin oral provocation testing, and investigate the tolerability of alternative medications, including acetaminophen, meloxicam, and celecoxib.

View Article and Find Full Text PDF

Background: Combination of targeted therapy and immune checkpoint inhibitors (ICIs) is a leading approach in the treatment of advanced hepatocellular carcinoma (HCC). However, an increased incidence of skin rashes poses a clinical challenge. Understanding the acute cutaneous adverse drug reactions (CADRs) during the early stage of the combination treatment is crucial.

View Article and Find Full Text PDF