A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Stability and reproducibility of proteomic profiles in epidemiological studies: comparing the Olink and SOMAscan platforms. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Limited data exist on the performance of high-throughput proteomics profiling in epidemiological settings, including the impact of specimen collection and within-person variability over time. Thus, the Olink (972 proteins) and SOMAscan7Kv4.1 (7322 proteoforms of 6596 proteins) assays were utilized to measure protein concentrations in archived plasma samples from the Nurses' Health Studies and Health Professionals Follow-Up Study. Spearman's correlation coefficients (r) and intraclass correlation coefficients (ICCs) were used to assess agreement between (1) 42 triplicate samples processed immediately, 24-h or 48-h after blood collection from 14 participants; and (2) 80 plasma samples from 40 participants collected 1-year apart. When comparing samples processed immediately, 24-h, and 48-h later, 55% of assays had an ICC/r ≥ 0.75 and 87% had an ICC/r ≥ 0.40 in Olink compared to 44% with an ICC/r ≥ 0.75 and 72% with an ICC/r ≥ 0.40 in SOMAscan7K. For both platforms, >90% of the assays were stable (ICC/r ≥ 0.40) in samples collected 1-year apart. Among 817 proteins measured with both platforms, Spearman's correlations were high (r > 0.75) for 14.7% and poor (r < 0.40) for 44.8% of proteins. High-throughput proteomics profiling demonstrated reproducibility in archived plasma samples and stability after delayed processing in epidemiological studies, yet correlations between proteins measured with the Olink and SOMAscan7K platforms were highly variable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9923770PMC
http://dx.doi.org/10.1002/pmic.202100170DOI Listing

Publication Analysis

Top Keywords

plasma samples
8
correlation coefficients
8
samples processed
8
processed 24-h
8
24-h 48-h
8
collected 1-year
8
1-year apart
8
samples
5
stability reproducibility
4
reproducibility proteomic
4

Similar Publications