Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8977019PMC
http://dx.doi.org/10.1186/s12967-022-03316-8DOI Listing

Publication Analysis

Top Keywords

correction deconvolution
4
deconvolution sarcoma
4
sarcoma methylomes
4
methylomes reveals
4
reveals varying
4
varying degrees
4
degrees of immune
4
of immune cell
4
cell infiltrates
4
infiltrates association
4

Similar Publications

Addressing Partial Volume Effects in Clinical PET Quantification: Modern Correction Strategies and Challenges.

PET Clin

August 2025

Laboratory of Translational Imaging in Oncology, Institut Curie, PSL, Inserm, LITO, Orsay, France. Electronic address:

Partial volume correction (PVC) is needed for an accurate quantification in clinical PET. Novel PVC methods can be divided into 4 categories: Post-reconstruction region-based methods, returning PVC regional values, making them suitable for quantification but not visual analysis ; post-reconstruction image enhancement techniques, either based on deconvolution or on the combination in the wavelet domain of PET functional information with high resolution information ; in-reconstruction resolution modelling, by incorporating a resolution model in an iterative reconstruction algorithm combined with regularization ; and deep learning-based approaches, which are based on networks that can be trained either with simulated data, real data, or data corrected with another PVC method, or can be self-supervised.

View Article and Find Full Text PDF

Ultrasound imaging systems rely on accurate point spread function (PSF) estimation to support advanced image quality enhancement techniques such as deconvolution and speckle reduction. Phase aberration, caused by sound speed inhomogeneity within biological tissue, is inevitable in ultrasound imaging. It distorts the PSF by increasing sidelobe level and introducing asymmetric amplitude, making PSF estimation under phase aberration highly challenging.

View Article and Find Full Text PDF

Frӧmer et al. (2024, Nature Human Behaviour) apply a deconvolution method to correct for component overlap in the event-related potential. They report that this method eliminates signatures of sensory evidence accumulation from response-aligned measurements of the centro-parietal positivity (CPP), suggesting that these signatures arise artifactually.

View Article and Find Full Text PDF

Lensless cameras have emerged as a common method to extend depth of field (DoF) in computational imaging due to their simple and compact structure. Current lensless extended depth-of-field (EDoF) cameras are primarily designed to generate a depth-invariant point spread function (PSF). This strategy often sacrifices diffraction efficiency to ensure PSF consistency across varying depths.

View Article and Find Full Text PDF

The miniaturization of optics through the use of two-dimensional metalenses has enabled novel applications in imaging. To date, single-lens imaging remains the most common configuration, partly due to the limited focusing efficiency of metalenses. This results in limitations when it comes to wavefront manipulation and, thus, unavoidable aberrations in the formed image that require computational deconvolution to deblur the image.

View Article and Find Full Text PDF