98%
921
2 minutes
20
Purpose Of Review: Cancer incidence and mortality are decreasing, but inequities in outcomes persist. This paper describes the San Francisco Cancer Initiative (SF CAN) as a model for the systematic application of epidemiological evidence to reduce the cancer burden and associated inequities.
Recent Findings: SF CAN is a multi-institutional implementation of existing evidence on the prevention and early detection of five common cancers (i.e., breast, prostate, colorectal, liver, and lung/tobacco-related cancers) accounting for 50% of cancer deaths in San Francisco. Five Task Forces follow individual logic models designating inputs, outputs, and outcomes. We describe the progress made and the challenges faced by each Task Force after 5 years of activity.
Summary: SF CAN is a model for how the nation's Comprehensive Cancer Centers are ideally positioned to leverage cancer epidemiology for evidence-based initiatives that, along with genuine community engagement and multiple stakeholders, can reduce the population burden of cancer.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8935108 | PMC |
http://dx.doi.org/10.1007/s40471-021-00280-7 | DOI Listing |
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Icon Cancer Centre Toowoomba, Toowoomba, Queensland, Australia.
Introduction: The role of imaging in radiotherapy is becoming increasingly important. Verification of imaging parameters prior to treatment planning is essential for safe and effective clinical practice.
Methods: This study described the development and clinical implementation of ImageCompliance, an automated, GUI-based script designed to verify and enforce correct CT and MRI parameters during radiotherapy planning.
Lab Anim Res
September 2025
Korea Model Animal Priority Center (KMPC), Seoul, Republic of Korea.
Background: Laboratory animal veterinarians play a crucial role as a bridge between the ethical use of laboratory animals and the advancement of scientific and medical knowledge in biomedical research. They alleviate pain and reduce distress through veterinary care of laboratory animals. Additionally, they enhance animal welfare by creating environments that mimic natural habitats through environmental enrichment and social associations.
View Article and Find Full Text PDFNutr J
September 2025
Department of Gastroenterology and Hepatology, Hangzhou Red Cross Hospital, 208 Huancheng Dong Road, Hangzhou, 310003, Zhejiang Province, China.
Background: The potential association between dietary inflammatory index (DII) and colorectal cancer (CRC) risk, as well as colorectal adenomas (CRA) risk, has been extensively studied, but the findings remain inconclusive. We conducted this systematic review and dose-response meta-analysis to investigate the relationship between the DII and CRC and CRA.
Methods: We comprehensively searched the PubMed, Embase, Cochrane Library, and Web of Science databases for cohort and case-control studies reporting the relationship between DII and CRA, or between DII and CRC, as of 15 July 2025.
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDF