98%
921
2 minutes
20
As an analytical method for aflatoxins in foods, the analytical method based on the notification by the director of the Food Safety Department, Pharmaceutical and Food Safety Bureau, Ministry of Health, Labour and Welfare (August 16, 2011) has been established. In order to improve the operability and analytical performance of the conventional method, this study aimed to construct an improved method that optimized selection of immunoaffinity column (IAC) and purifying condition, and omitted evaporation after the purification with IAC. In the recovery test performed by adding 2.5 ng/g of aflatoxin B1, B2, G1 and G2 standard solutions into 9 kinds of food samples, the improved method achieved the established target values: 77.0-99.7% of recovery, 1.7-5.6% of intra-assay coefficient of validation, and 0.9-3.6% of inter-assay of coefficient of variation, respectively. The improved method also achieved 4.3-10.5% greater recovery and 1.5 hours shorter preparation time than the conventional one. These results indicate applicability of the improved method for 9 kinds of foods and its efficacy as an analytical method for aflatoxins in foods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3358/shokueishi.63.43 | DOI Listing |
BMC Glob Public Health
September 2025
Connell School of Nursing, Boston College, Chestnut Hill, MA, USA.
Background: Sierra Leone has the world's third highest incidence of maternal mortality, with 443 deaths per 100,000 live births. Strengthening the country's midwifery workforce is essential to providing adequate maternal healthcare and reducing preventable perinatal mortality. In support of this goal, we developed and implemented a midwifery preceptor program (MPP) to train experienced midwives to effectively mentor new and student midwives.
View Article and Find Full Text PDFAlzheimers Res Ther
September 2025
Department of Neurology, Saarland University, Kirrberger Straße, 66421, Homburg/Saar, Germany.
Background: Alzheimer's disease (AD) patients and animal models exhibit an altered gut microbiome that is associated with pathological changes in the brain. Intestinal miRNA enters bacteria and regulates bacterial metabolism and proliferation. This study aimed to investigate whether the manipulation of miRNA could alter the gut microbiome and AD pathologies.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Clinical Imaging Physics Group, Duke University Health System, Durham, North Carolina, USA.
Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.
View Article and Find Full Text PDFJ Intensive Care
September 2025
German Center for Vertigo and Balance Disorders, Ludwig-Maximilians-Universitat (LMU), University Hospital Grosshadern, Munich, Germany.
Background: Survivors of critical illness frequently face physical, cognitive and psychological impairments after intensive care. Sensorimotor impairments potentially have a negative impact on participation. However, comprehensive understanding of sensorimotor recovery and participation in survivors of critical illness is limited.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDF