Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The Covid-19 outbreak challenged health systems around the world to design and implement cost-effective devices produced locally to meet the increased demand of mechanical ventilators worldwide. This study evaluates the physiological responses of healthy swine maintained under volume- or pressure-controlled mechanical ventilation by a mechanical ventilator implemented to bring life-support by automating a resuscitation bag and closely controlling ventilatory parameters. Physiological parameters were monitored in eight sedated animals (t0) prior to inducing deep anaesthesia, and during the next six hours of mechanical ventilation (t1-7). Hemodynamic conditions were monitored periodically using a portable gas analyser machine (i.e. BEecf, carbonate, SaO2, lactate, pH, PaO2, PaCO2) and a capnometer (i.e. ETCO2). Electrocardiogram, echocardiography and lung ultrasonography were performed to detect in vivo alterations in these vital organs and pathological findings from necropsy were reported. The mechanical ventilator properly controlled physiological levels of blood biochemistry such as oxygenation parameters (PaO2, PaCO2, SaO2, ETCO2), acid-base equilibrium (pH, carbonate, BEecf), and perfusion of tissues (lactate levels). In addition, histopathological analysis showed no evidence of acute tissue damage in lung, heart, liver, kidney, or brain. All animals were able to breathe spontaneously after undergoing mechanical ventilation. These preclinical data, supports the biological safety of the medical device to move forward to further evaluation in clinical studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8893637PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0264774PLOS

Publication Analysis

Top Keywords

mechanical ventilator
12
mechanical ventilation
12
pao2 paco2
8
mechanical
7
biological evaluation
4
evaluation mechanical
4
ventilator operates
4
operates controlling
4
controlling automated
4
automated manual
4

Similar Publications

Background: Optimal oral care is essential in preventing non-ventilator hospital-associated pneumonia and enhancing patient comfort. However, nurses' clinical oral care practices for patients not on mechanical ventilation in the intensive care unit are both underreported and understudied.

Aim: To explore intensive care nurses' clinical oral care practices for patients not on mechanical ventilation in intensive care units.

View Article and Find Full Text PDF

Mean Airway Pressure-An Informative but Overlooked Indicator of Mechanical Power.

Crit Care Explor

September 2025

Division of Pulmonary, Allergy, Critical Care, and Sleep, University of Minnesota, Minneapolis, MN.

Mean airway pressure, a monitored variable continuously available on the modern ventilator, is the pressure measured at the airway opening averaged over the time needed to complete the entire respiratory cycle. Mean airway pressure is well recognized to connect three key physiologic processes in mechanical ventilation: physical stretch, cardiovascular dynamics, and pulmonary gas exchange. Although other parameters currently employed in adults to determine "safe" ventilation are undoubtedly valuable for daily practice, all have limitations for continuous monitoring of ventilation hazard.

View Article and Find Full Text PDF

Background: Procalcitonin (PCT) is used in the diagnosis of sepsis. Its capability as a prognostic marker is unclear. The association between PCT and paediatric intensive care unit (PICU) outcomes has not been investigated in the South African setting.

View Article and Find Full Text PDF

Asthma is one of the most prevalent chronic respiratory illnesses, significantly impacting patients through shortness of breath and even death. Acute exacerbations are usually controlled with a short-acting beta agonist, such as an albuterol inhaler, as well as long-acting agents to prevent the occurrence of exacerbations and status asthmaticus. Status asthmaticus is an emergent episode of asthma that is refractory to standard treatment.

View Article and Find Full Text PDF