Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Optically-pumped magnetometers (OPMs) are an established alternative to superconducting sensors for magnetoencephalography (MEG), offering significant advantages including flexibility to accommodate any head size, uniform coverage, free movement during scanning, better data quality and lower cost. However, OPM sensor technology remains under development; there is flexibility regarding OPM design and it is not yet clear which variant will prove most effective for MEG. Most OPM-MEG implementations have either used single-axis (equivalent to conventional MEG) or dual-axis magnetic field measurements. Here we demonstrate use of a triaxial OPM formulation, able to characterise the full 3D neuromagnetic field vector. We show that this novel sensor is able to characterise magnetic fields with high accuracy and sensitivity that matches conventional (dual-axis) OPMs. We show practicality via measurement of biomagnetic fields from both the heart and the brain. Using simulations, we demonstrate how triaxial measurement offers improved cortical coverage, especially in infants. Finally, we introduce a new 3D-printed child-friendly OPM-helmet and demonstrate feasibility of triaxial measurement in a five-year-old. In sum, the data presented demonstrate that triaxial OPMs offer a significant improvement over dual-axis variants and are likely to become the sensor of choice for future MEG systems, particularly for deployment in paediatric populations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9135302PMC
http://dx.doi.org/10.1016/j.neuroimage.2022.119027DOI Listing

Publication Analysis

Top Keywords

demonstrate triaxial
12
neuromagnetic field
8
triaxial measurement
8
triaxial
5
triaxial detection
4
detection neuromagnetic
4
field optically-pumped
4
optically-pumped magnetometry
4
magnetometry feasibility
4
feasibility application
4

Similar Publications

Application of particle swarm optimization to non-orthogonal error correction in SAFEM total magnetic intensity measurements.

Rev Sci Instrum

September 2025

State Key Laboratory of Deep Earth Exploration and Imaging, Jilin University, Changchun 130026, People's Republic of China.

In the semi-airborne frequency-domain electromagnetic (SAFEM) method, the total magnetic intensity (TMI) is derived from the vector synthesis of triaxial inductive magnetic sensors. However, non-orthogonal errors in the sensors introduce measurement inaccuracies. Traditional calibration techniques are unsuitable for induction magnetic sensors because they require either static magnetic field measurements or complex alternating current reference fields.

View Article and Find Full Text PDF

The growing global prevalence of orthopedic conditions associated with an aging population has significantly increased the clinical demand for orthopedic implants. However, postoperative complications, including postoperative bleeding, implant associated infections (IAIs), and inadequate osteogenesis, continue to limit surgical outcomes. To simultaneously mitigate these challenges, a multifunctional electrospun fibrous coating (EFC) is developed, with an inner tri-layer core-sheath nanostructure to separately load tranexamic acid (TXA), fenoprofen (Fen), and puerarin (Pue) in the shell, middle, and core sections, respectively.

View Article and Find Full Text PDF

To investigate the failure behavior and cracking mechanisms in surrounding rock, a true triaxial experimental system and digital imaging were employed to perform compression tests on sandstone specimens containing preexisting flaws. Experimental results revealed the propagation characteristics of microfractures under stress concentration conditions and their correlation with failure patterns. Furthermore, a fracture propagation model was implemented to evaluate the susceptibility of surrounding rock to failure.

View Article and Find Full Text PDF

Purpose: To quantify real-time hand-foot coupling in tennis and test whether the coupling pattern differs by playing standard.

Methods: Fifteen nationally certified second-level male athletes and fifteen recreational beginners performed multi-directional swings, alternating forehand-backhand groundstrokes and serve-and-volley sequences while tri-axial ankle acceleration and racket-grip force were synchronously recorded in wearable inertial measurement units (IMUs). Grip metrics (mean force, peak force, force duration) and acceleration magnitudes were analysed with MANOVA and Hedges' g effect sizes, followed by the Benjamini-Hochberg correction (α = 0.

View Article and Find Full Text PDF

The increasing depth of coal mine construction has led to complex geological conditions involving high ground stress and elevated groundwater levels, presenting new challenges for water-sealing technologies in rock microfissure grouting. This study investigates ultrafine cement grouting in microfissures through systematic analysis of slurry properties and grouting simulations. Through systematic analysis of ultrafine cement grout performance across water-cement (W/C) ratios, this study establishes optimal injectable mix proportions.

View Article and Find Full Text PDF