A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The use of circular and hybrid external skeletal fixation systems to repair open tibial fractures in large ruminants: a report of six clinical cases. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A prospective clinical study consisting of six bovines (200-300 kg body weight) undergoing open tibial fractures was carried out, to evaluate the use of circular and hybrid external skeletal fixation (ESF) systems for open tibial fracture repair in large ruminants. The ESF systems consisting of 4 full rings (n = 2), 8 half-rings (n = 1), 2 full rings with 2 sidebars (n = 2) or 2 full rings with 4 sidebars (n = 1) were used to treat open tibial fractures. The healing progress of the animals was evaluated based on different clinical and radiographic examinations. The level of fracture reduction, alignment, and fixation ranged between satisfactory to adequate in all the animals. The fixators were well tolerated and maintained by the animals till the complete repair of the fracture. Adequate fracture healing with satisfactory functional recovery was observed in all the animals in about 3-4 months. The different designs of ESFs were found to provide adequate stability in open tibial fractures in animals weighing 200-300 kg. However, the fixators need to be evaluated in numerous clinical cases to establish their suitability in routine clinical settings.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11259-022-09884-wDOI Listing

Publication Analysis

Top Keywords

open tibial
20
tibial fractures
16
full rings
12
circular hybrid
8
hybrid external
8
external skeletal
8
skeletal fixation
8
large ruminants
8
clinical cases
8
esf systems
8

Similar Publications