98%
921
2 minutes
20
Campylobacter fetus can cause intestinal and systemic disease in humans and are well-established veterinary and economic pathogens. We report the complete genomic sequences of two C. fetus subsp. fetus (Cff) isolates recovered in 2017 (CITCf01) and 2018 (CITCf02) from a case of recurrent prosthetic valve endocarditis. Both were capable of growth aerobically. Their genomes were found to be highly conserved and syntenic with 99.97% average nucleotide identity (ANI) while differences in their respective sap loci defined the temporal separation of their genomes. Based on core genome phylogeny and ANI of 83 Cff genomes belonging to the previously described human-associated Cff lineage, CITCf01 and CITCf02 grouped in a clade of 11 sequence type (ST)3 Cff (including the Cff type strain NCTC 10842T). CITCf01 and CITCf02 were marked for their lack of unique genomic features when compared to isolates within the subspecies and the type strain in particular. We identified point mutations in oxidative stress response genes, among others, that may contribute to aerobiosis. We report a case of Cff causing relapsed prosthetic valve endocarditis and we highlight the sap island as a polymorphic site within the genetically stable ST3 lineage, central to pathogenicity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/femspd/ftab055 | DOI Listing |
Rev Cardiovasc Med
August 2025
Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.
Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.
View Article and Find Full Text PDFJTCVS Open
August 2025
Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minn.
Objective: To evaluate the early postoperative morbidity, mortality, and prosthetic conduit function of patients who underwent aortic root replacement using a prefabricated bioprosthetic aortic valved conduit.
Methods: Single-center retrospective review of 124 consecutive adult patients who underwent aortic root replacement with a certified prefabricated bioprosthetic aortic valved conduit from 2021 to December 2023.
Results: Indications for operation were aortic aneurysms (n = 92), endocarditis (n = 12), deterioration of prior valve prosthesis (n = 13), and aortic dissection (n = 6).
Cureus
August 2025
Internal Medicine, Ronald Reagan University of California Los Angeles Medical Center, Los Angeles, USA.
Although generally considered harmless commensals or beneficial probiotics, species can act as opportunistic pathogens under certain clinical conditions. We describe a case of high-grade bacteremia in a 59-year-old man with a history of aortic root dilation status post Bentall procedure and bioprosthetic aortic valve replacement. The suspected source was recent dental instrumentation.
View Article and Find Full Text PDFSurg Case Rep
August 2025
Department of Cardiac and Vascular Surgery, Dokkyo Medical University School of Medicine, Shimotsugagun, Tochigi, Japan.
Introduction: Prosthetic valve endocarditis following aortic root replacement (ARR) typically necessitates redo-ARR, which involves complete graft removal, extensive aortic root dissection, and coronary reimplantation. This highly invasive procedure carries substantial surgical risk, including high operative mortality. In select high-risk patients without evidence of prosthetic graft infection, alternative surgical strategies may reduce procedural complexity and improve outcomes.
View Article and Find Full Text PDFMultimed Man Cardiothorac Surg
September 2025
Department of Cardiovascular Surgery, Marmara University Pendik Research and Training Hospital, Istanbul, Turkey.
Complete detachment of the aortic root following a Bentall procedure is an exceptionally rare complication. The vast majority of reported cases are secondary to prosthetic valve endocarditis or underlying vasculitis. Currently, the most reliable treatment for aortic root dehiscence-particularly in the context of prosthetic valve endocarditis-is repeat root replacement, typically via a second Bentall procedure or with the use of a homograft or allograft.
View Article and Find Full Text PDF