Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: We aimed to simulate blood flow at an aortic dissection in an in vitro vascular model and assess the impact of the cannulation method on visceral perfusion.

Methods: An aortic-dissection model with an acrylic aortic wall and silicone intimal flap was developed to study visceral perfusion under various cannulation conditions. The primary tear was placed in the proximal descending aorta and the re-entry site in the left common iliac artery. A cardiovascular pump was used to reproduce a normal pulsatile aortic flow and a steady cannulation flow. Axillary and axillary plus femoral cannulation were compared at flow rates of 3-7 l/min. Haemodynamics were analysed by using four-dimensional flow magnetic resonance imaging.

Results: Axillary cannulation (AC) was found to collapse the true lumen at the coeliac and superior mesentery arteries, while combined axillary and femoral cannulation did not change the size of the true lumen. Combined axillary and femoral cannulation resulted in a larger visceral flow than did AC alone. When axillary plus femoral cannulation was used, the visceral flow increased by 125% at 3 l/min, by 89% at 4 l/min, by 67% at 5 L/min, by 98% at 6 l/min and by 101% at 7 l/min, respectively, compared to those with the AC only.

Conclusions: Our model was useful to understanding the haemodynamics in aortic dissection. In this specific condition, we confirmed that the intimal flap motion can partially block blood flow to the coeliac and superior mesenteric arteries and that additional femoral cannulation can increase visceral perfusion.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejcts/ezab508DOI Listing

Publication Analysis

Top Keywords

femoral cannulation
24
axillary femoral
16
visceral perfusion
12
aortic dissection
12
cannulation
10
flow
8
blood flow
8
intimal flap
8
flow axillary
8
true lumen
8

Similar Publications

Objective: To explore the clinical efficacy of internal fixation of locking compression plate and Cannulated Screw in treatment of elderly femoral neck fractures.

Methods: 175 patients with femoral neck fractures admitted to our hospital from January 2022 to December 2022 were enrolled in the study. 93 cases in the control group were treated with Cannulated Screw internal fixation, and 82 cases in the observation group were treated with locking plate internal fixation.

View Article and Find Full Text PDF

Introduction Proximal femoral fractures are a major cause of disability, particularly in aging populations, with an increasing incidence. Although osteosynthesis remains the first-line treatment, failures are common due to various complications. Total hip arthroplasty (THA) is the preferred salvage procedure in such cases, despite its technical challenges.

View Article and Find Full Text PDF

Objective: To compare 6- and 12-month results of femoral artery repair with xenopericardial and autologous venous patch in hybrid treatment of critical lower limb ischemia.

Material And Methods: A retrospective analysis included 60 patients with critical lower limb ischemia who underwent hybrid treatment (balloon angioplasty and stenting of iliac arteries and open reconstruction of femoral arteries). Patients were divided into 2 groups by 30 people depending on femoral artery repair (group 1 - autologous venous patch, group 2 - xenopericardial patch).

View Article and Find Full Text PDF

Rationale: This case report aims to highlight a rare but life-threatening complication of femoral venous catheterization and to describe a novel endovascular technique for its management. Non-tunneled femoral catheters provide rapid vascular access for emergency dialysis (e.g.

View Article and Find Full Text PDF

Purpose: Femoral neck fractures are clinically rare and are associated with a high risk of complications in children. Traditional internal fixation implants such as Kirschner wires and partial-thread cannulated screws (PTCS) have complications such as screw withdrawal and internal fixation failure. To address this problem, in this study we investigated the effectiveness of headless cannulated compression screws (HCCS) in the treatment of femoral neck fractures in children patients.

View Article and Find Full Text PDF