Article Abstract

Early detection of SARS-CoV-2 infection is critical to reduce asymptomatic and presymptomatic transmission, curb the spread of variants, and maximize treatment efficacy. Low-analytical-sensitivity nasal-swab testing is commonly used for surveillance and symptomatic testing, but the ability of these tests to detect the earliest stages of infection has not been established. In this study, conducted between September 2020 and June 2021 in the greater Los Angeles County, California, area, initially SARS-CoV-2-negative household contacts of individuals diagnosed with COVID-19 prospectively self-collected paired anterior-nares nasal-swab and saliva samples twice daily for viral-load quantification by high-sensitivity reverse-transcription quantitative PCR (RT-qPCR) and digital-RT-PCR assays. We captured viral-load profiles from the incidence of infection for seven individuals and compared diagnostic sensitivities between respiratory sites. Among unvaccinated persons, testing saliva with a high-analytical-sensitivity assay detected infection up to 4.5 days before viral loads in nasal swabs reached concentrations detectable by low-analytical-sensitivity nasal-swab tests. For most participants, nasal swabs reached higher peak viral loads than saliva but were undetectable or at lower loads during the first few days of infection. High-analytical-sensitivity saliva testing was most reliable for earliest detection. Our study illustrates the value of acquiring early (within hours after a negative high-sensitivity test) viral-load profiles to guide the appropriate analytical sensitivity and respiratory site for detecting earliest infections. Such data are challenging to acquire but critical to designing optimal testing strategies with emerging variants in the current pandemic and to respond to future viral pandemics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8849374PMC
http://dx.doi.org/10.1128/JCM.01785-21DOI Listing

Publication Analysis

Top Keywords

nasal swabs
12
saliva samples
8
low-analytical-sensitivity nasal-swab
8
viral-load profiles
8
viral loads
8
swabs reached
8
saliva
5
infection
5
testing
5
quantitative sars-cov-2
4

Similar Publications

Introduction: The aim of this study was to compare the performance of different clinical specimens-nasopharyngeal (NP) swabs collected by healthcare professionals (HCP-NP), self-collected nasal swabs (Sc-N), and saliva samples (S)-in diagnostic tests for investigating severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA and influenza A/B RNA.

Methodology: These clinical samples were collected from 404 symptomatic cases and tested with the SARS-CoV-2 and influenza A/B RNA tests on the cobas 6800 System of Roche Molecular Systems (Roche Molecular Systems, Pleasanton, USA). The SARS-CoV-2 or influenza virus infection status was determined for all patients based on the predefined criteria and corresponding algorithms.

View Article and Find Full Text PDF

4-Octyl Itaconate ameliorates diesel exhaust particle-induced oxidative stress in nasal epithelial cells.

Front Immunol

September 2025

Department of Molecular Pneumology, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Universitätsklinikum Erlangen, Erlangen, Germany.

Background And Objective: Particulate matters such as diesel exhaust particles induce oxidative stress in cells and thereby have a negative impact on health. The aim of this study was to test whether the membrane-permeable, anti-inflammatory metabolite 4-Octyl Itaconate can counteract the oxidative stress induced by diesel exhaust particles and to analyze the downstream-regulated pathways both in human nasal epithelial cells and PBMCs.

Methods: Human nasal epithelial cells were cultured from nasal swabs, and the response of the cells to diesel exhaust particles either alone or in combination with 4-Octyl Itaconatee was investigated using RNA sequencing, qPCR, and cytokine measurement.

View Article and Find Full Text PDF

BACKGROUND The SENTINEL influenza surveillance system has been used in Poland since 2004, incorporating both epidemiological and virological monitoring of influenza viruses. SENTINEL works in cooperation with general practitioners, 16 Voivodship Sanitary Epidemiological Stations (VSES), and the National Influenza Centre (NIC). NON-SENTINEL samples are collected from places that do not participate in the SENTINEL program.

View Article and Find Full Text PDF

Effect of maternal HIV status on the early neonatal microbiome.

J Pediatric Infect Dis Soc

September 2025

Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, U. S. A.

Microbiome disruption is a proposed mechanism for the observed differences in child health outcomes by maternal HIV status, but the early neonatal microbiome of HIV-exposed (HE) newborns is not well studied. We used 16S ribosomal ribonucleic acid sequencing to analyze the microbiome composition of nasal, skin, and rectal samples collected ≤72 hours after birth from 57 hospitalized neonates in Botswana, 33% of whom were HE. Beta diversity differed by anatomic compartment (p=.

View Article and Find Full Text PDF

Objective: The objective of this study is to evaluate diagnostic efficacy of targeted next-generation sequencing (tNGS) on nasopharyngeal (NP) swabs in pediatric community-acquired pneumonia (CAP).

Methods: We conducted a retrospective analysis, compiling nasal and bronchoalveolar lavage fluid (BALF) specimens from a cohort of 147 children diagnosed with CAP at Tongling Maternal and Child Health Hospital from May 2023 to October 2024. The diagnostic accuracy of nasal tNGS was evaluated and compared against BALF tNGS and conventional microbiological tests (CMT), which included microbial culture and targeted polymerase chain reaction assays.

View Article and Find Full Text PDF