Article Abstract

A comprehensive approach is proposed to systematically determine the optimal mode of operation between continuous and batch injectable manufacturing considering product and market conditions. At the core of this approach are two integrated complete mathematical modules for discrete and continuous injectable manufacturing, which are supplemented with an economic evaluation module that can then be used to explore the impact of all relevant process parameters (e.g., lot-size, number of operators, solubility, product demand, raw material costs). When the developed approach was applied to two case studies, it was found that batch production was preferred at low to moderate solution (raw material) costs. In contrast, at higher solution costs, the preference for batch and continuous production processes changed back and forth as the annual product demand changed. The study also found that continuous production processes became increasingly preferred at medium to large final dosage volumes and a competitive alternative even at moderate solution costs. From a decision-making point of view, batch injectable manufacturing will be preferred over the novel continuous manufacturing technology unless there is a significant economic incentive to overcome the perceived technology risk. The proposed approach is intended as a decision-support tool for pharmaceutical process engineers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2021.121353DOI Listing

Publication Analysis

Top Keywords

injectable manufacturing
16
continuous batch
8
batch injectable
8
product demand
8
raw material
8
material costs
8
moderate solution
8
solution costs
8
continuous production
8
production processes
8

Similar Publications

Monoclonal antibodies (mAb) have transformed modern medicine, offering targeted therapies for cancer, autoimmune disorders, and infectious diseases. To enhance patient convenience, subcutaneous administration is increasingly prioritized, requiring highly concentrated formulations. However, high viscosity of these formulations hinders manufacturability, injectability, and stability.

View Article and Find Full Text PDF

Amorphous silicon resistors enable smaller pixels in photovoltaic retinal prosthesis.

J Neural Eng

September 2025

Hansen Experimental Physics Laboratory, Stanford University, 452 Lomita Mall, Stanford, California, 94305, UNITED STATES.

Clinical trials of the photovoltaic subretinal prosthesis PRIMA demonstrated feasibility of prosthetic central vision with resolution matching its 100 μm pixel width. To improve prosthetic acuity further, pixel size should be decreased. However, there are multiple challenges, one of which is related to accommodating a compact shunt resistor within each pixel that discharges the electrodes between stimulation pulses and helps increase the contrast of the electric field pattern.

View Article and Find Full Text PDF

An injectable hyaluronic acid-based hydrogel for the treatment of breast cancer.

Colloids Surf B Biointerfaces

September 2025

Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an 710127, China; Shaanxi Key Laboratory of Biomaterials and Synthetic Biology, Shaanxi R&D Center of Biomaterials and Fermentation

In this study, we develop a hyaluronic-tannic acid (HA-TA) hydrogel loaded with Cu nanoparticles attach to MXene (MXene@Cu) to explore its potential as a targeted breast cancer treatment. The MXene@Cu nanosheets exhibit activity in depleting glutathione (GSH) and inducing reactive oxygen species (ROS) through the Fenton-like reaction. They can down-regulate the activity of glutathione peroxidase 4 (GPX4), leading to the accumulation of lipid peroxides (LPO) and inducing ferroptosis in tumor cells.

View Article and Find Full Text PDF

Accurate brain signal recording and precise electrode placement are critical for the success of neuromodulation therapies such as deep brain stimulation (DBS). Addressing these challenges requires deep brain electrodes that provide high-quality, stable recordings while remaining compatible with high-resolution medical imaging modalities like magnetic resonance imaging (MRI). Moreover, such electrodes shall be cost-effective, easy to manufacture, and patient-compatible.

View Article and Find Full Text PDF

Unlabelled: Drooling is a common problem in children with neurodisability, and refractory cases may require surgery. Our aim was to assess whether a child's response to salivary botulinum toxin injections would predict success or failure from subsequent surgical intervention. Retrospective case note review of all children undergoing drooling surgery between 1st January 2007 and 31st December 2023 at the Royal Hospital for Children, Glasgow.