Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The electrical impedance tomography (EIT) technology is an important medical imaging approach to show the electrical characteristics and the homogeneity of a tissue region noninvasively. Recently, this technology has been introduced to the Robot Assisted Minimally Invasive Surgery (RAMIS) for assisting the detection of surgical margin with relevant clinical benefits. Nevertheless, most EIT technologies are based on a fixed multiple-electrodes probe which limits the sensing flexibility and capability significantly. In this study, we present a method for acquiring the EIT measurements during a RAMIS procedure using two already existing robotic forceps as electrodes. The robot controls the forceps tips to a series of predefined positions for injecting excitation current and measuring electric potentials. Given the relative positions of electrodes and the measured electric potentials, the spatial distribution of electrical conductivity in a section view can be reconstructed. Realistic experiments are designed and conducted to simulate two tasks: subsurface abnormal tissue detection and surgical margin localization. According to the reconstructed images, the system is demonstrated to display the location of the abnormal tissue and the contrast of the tissues' conductivity with an accuracy suitable for clinical applications.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC46164.2021.9629590DOI Listing

Publication Analysis

Top Keywords

electrical impedance
12
impedance tomography
8
detection surgical
8
surgical margin
8
electric potentials
8
abnormal tissue
8
robot-assisted electrical
4
impedance scanning
4
scanning system
4
electrical
4

Similar Publications

Hardness of meat is one of the most important textural properties noted while eating. Bromelain, found in pineapples, is an enzyme that degrades collagen, a factor that affects meat hardness. The latter is generally evaluated based on shear strength and texture; however, such methods are destructive.

View Article and Find Full Text PDF

This study introduces a back filter installed at the end of the exhaust pipe of city buses. The impact of the metal type used in its construction on the absorption of suspended particles and the reduction of sulfides in diesel engine exhaust gases is investigated. The back filter is constructed from three metals: copper, zinc, and nickel.

View Article and Find Full Text PDF

This study investigated the association between parameters derived from bioelectrical impedance spectroscopy (BIS) and arterial stiffness, as measured using carotid-femoral pulse wave velocity (cfPWV) and brachial-ankle pulse wave velocity (baPWV) pulse wave velocities. Data from 292 Japanese adults were analyzed. BIS was used to assess the phase angle (PhA), extracellular water to intracellular water ratio (ECW/ICW), and body cell mass-to-free fat mass ratio (BCM/FFM).

View Article and Find Full Text PDF

Microneedle electrodes for electromyography.

Biosens Bioelectron

September 2025

UCD Centre for Biomedical Engineering, University College Dublin, Belfield, Dublin, 4, Ireland; School of Mechanical & Materials Engineering, University College Dublin, Belfield, Dublin, 4, Ireland. Electronic address:

Surface electromyography (sEMG) is the measurement of the electrical activity of muscle and is extensively used in fundamental research and across many applications in health and sport. Conventional surface electrode technology can suffer from poor signal quality, particularly when used outside the laboratory, requires careful skin preparation prior to electrode application, and can be challenging when used for long-term recording. These limitations have challenged the translation of sEMG to widespread clinical application.

View Article and Find Full Text PDF

Precise delivery of nanoliter-scale reagents is essential for high-throughput biochemical assays, yet existing platforms often lack real-time control and selective content fusion. Conventional methods rely on passive encapsulation or stochastic pairing, limiting both throughput and biochemical specificity. Here, we introduce an on-demand nanoliter delivery platform that seamlessly integrates electrical sensing, triggered droplet merging, and passive sorting in a single continuous flow.

View Article and Find Full Text PDF