Article Abstract

Introduction: Frequent glucose monitoring is essential to obtain glucose control. This is done by periodic self-monitoring of blood glucose (SMBG) using finger-prick testing, or by using continuous glucose monitoring devices, wherein a sensor records interstitial glucose data automatically. This study assessed the cost-effectiveness of using the FreeStyle Libre Flash Continuous Glucose Monitoring System (FSL) compared to SMBG in individuals with type 2 diabetes (T2D) treated with insulin from a Swedish societal perspective.

Methods: Cost-effectiveness analysis was conducted using the IQVIA Core Diabetes model v9.5, with demographic and clinical inputs from a real-world study using Swedish National Diabetes Register data. Two cohorts of individuals with T2D were considered based on baseline HbA1C (HbA1c: 8-9% [64-75 mmol/mol]; HbA1c: 9-12% [75-108 mmol/mol]). HbA1c reductions with FSL were - 0.41% (- 4 mmol/mol; SD: 0.94%-10 mmol/mol) and - 1.30% (- 14 mmol/mol; SD: 1.40%-15 mmol/mol) for the two cohorts, respectively. Utilities, treatment costs and diabetes-related complication costs were obtained from published sources. Analyses were conducted over a lifetime horizon, applying annual discounting of 3% on costs and effects. Scenario analyses and probabilistic sensitivity analyses were performed.

Results: Individuals with T2D who had a baseline HbA1c of 8-9% (64-75 mmol/mol) and 9-12% (75-108 mmol/mol) and used FSL gained 0.50 and 0.57 quality-adjusted life-years (QALYs), respectively, at an incremental cost of SEK109,957 and SEK82,170 compared to SMBG, generating an incremental cost-utility ratio of SEK219,127 and SEK144,412 per QALY gained. Assuming a willingness-to-pay threshold of SEK300,000 per QALY gained, FSL use was considered cost-effective compared to SMBG for the majority of the individuals in both the lower and higher HbA1c cohorts. The key driver identified was the additional quality-of-life benefit that applied to FSL use.

Conclusion: The FreeStyle Libre Flash Continuous Glucose Monitoring System is a cost-effective glucose monitoring alternative to SMBG for individuals with T2D in Sweden who are treated with insulin but are not reaching their glycaemic goals.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8586127PMC
http://dx.doi.org/10.1007/s13300-021-01172-1DOI Listing

Publication Analysis

Top Keywords

glucose monitoring
20
freestyle libre
12
continuous glucose
12
compared smbg
12
individuals t2d
12
glucose
9
cost-effectiveness freestyle
8
blood glucose
8
individuals type
8
type diabetes
8

Similar Publications

Self-Propelled Magnetic Micromotor-Functionalized DNA Tile System for Autonomous Capture of Circulating Tumor Cells in Clinical Diagnostics.

Adv Sci (Weinh)

September 2025

Key Laboratory of Emergency and Trauma of Ministry of Education, The First Affiliated Hospital, NHC Key Laboratory of Tropical Disease Control, School of Tropical Medicine & The Second Affiliated Hospital, Hainan Medical University, Haikou, 571199, China.

Circulating tumor cells (CTCs) carry intact tumor molecular information, making them invaluable for personalized cancer monitoring. However, conventional capture methods, relying on passive diffusion, suffer from low efficiency due to insufficient collision frequency, severely limiting clinical utility. Herein, a magnetic micromotor-functionalized DNA-array hunter (MMDA hunter) is developed by integrating enzyme-propelled micromotors, magnetic nanoparticles, and nucleic acid aptamers into distinct functional partitions of a DNA tile self-assembly structure.

View Article and Find Full Text PDF

Background: Chronic kidney disease (CKD) management was largely centered around renin-angiotensin-aldosterone system inhibitors (RAASi) optimization, until recent emergence of novel therapeutics. However, slow adoption of guideline-directed therapy leaves patients vulnerable to disease progression. In 2022, a data-driven informatics approach was introduced to track real-time adherence to best practices.

View Article and Find Full Text PDF

Diabetes management during the end of life.

Br J Nurs

September 2025

Macmillan Palliative and End of Life Care Practice Educator and Specialist Nurse Practitioner, Northampton General Hospital.

For individuals with diabetes, maintaining optimal glycaemic control is essential to reduce the risk of long-term complications. However, as patients approach the end of life, the emphasis on tight glycaemic targets becomes less relevant. Instead, the primary goal shifts to maintaining blood glucose levels within a range that minimises the risk of hypoglycaemia and prevents symptomatic hyperglycaemia, thereby ensuring comfort and quality of life.

View Article and Find Full Text PDF

Background: Despite advances, glycemic control in people with type 2 diabetes (PwT2D) treated with oral antidiabetic medications (ADMs) often remains suboptimal. Continuous glucose monitoring (CGM) has shown promise in diabetes management, offering real-time insights into glucose trends. This study evaluates the impact of transitioning from conventional self-monitoring of blood glucose (SMBG) to CGM on glycemic outcomes and self-management in PwT2D receiving oral ADMs.

View Article and Find Full Text PDF

Aloe emodin functionalized dual-channel label with self-adhesion and hydrophobicity for visual monitoring of seafood freshness.

Int J Biol Macromol

September 2025

Key Laboratory of Jianghuai Agricultural Product Fine Processing and Resource Utilization of Ministry of Agriculture and Rural Affairs, College of Food and Nutrition, Anhui Agricultural University, Hefei, 230036, China. Electronic address:

In this study, aloe emodin and β-d-glucose pentaacetate were added into potato starch/polyvinyl alcohol for the construction of colorimetric/fluorescent dual-pass intelligent response labels. Inspired by the lotus leaf structure, retained the advantages of the label itself and solved the hydrophilic problem of the label, and further developed a multi-functional dual-channel smart label with hydrophobicity and self-adhesion. The water contact angle of the prepared T-AEB label was 120.

View Article and Find Full Text PDF