Article Abstract

Significance: Peripheral pitting edema is a clinician-administered measure for grading edema. Peripheral edema is graded 0, 1  +  , 2  +  , 3  +  , or 4  +  , but subjectivity is a major limitation of this technique. A pilot clinical study for short-wave infrared (SWIR) molecular chemical imaging (MCI) effectiveness as an objective, non-contact quantitative peripheral edema measure is underway.

Aim: We explore if SWIR MCI can differentiate populations with and without peripheral edema. Further, we evaluate the technology for correctly stratifying subjects with peripheral edema.

Approach: SWIR MCI of shins from healthy subjects and heart failure (HF) patients was performed. Partial least squares discriminant analysis (PLS-DA) was used to discriminate the two populations. PLS regression (PLSR) was applied to assess the ability of MCI to grade edema.

Results: Average spectra from edema exhibited higher water absorption than non-edema spectra. SWIR MCI differentiated healthy volunteers from a population representing all pitting edema grades with 97.1% accuracy (N  =  103 shins). Additionally, SWIR MCI correctly classified shin pitting edema levels in patients with 81.6% accuracy.

Conclusions: Our study successfully achieved the two primary endpoints. Application of SWIR MCI to monitor patients while actively receiving HF treatment is necessary to validate SWIR MCI as an HF monitoring technology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8541742PMC
http://dx.doi.org/10.1117/1.JBO.26.10.105002DOI Listing

Publication Analysis

Top Keywords

swir mci
24
peripheral edema
16
pitting edema
12
edema
9
heart failure
8
failure patients
8
short-wave infrared
8
molecular chemical
8
chemical imaging
8
mci
8

Similar Publications

This work presents an adaptable and fully automated approach for calibrating hyperspectral images (HSI) acquired using a pushbroom (line-scan) system. The proposed method enables simultaneous spectral, intensity, and spatial calibration while determining the spectral and spatial resolution of the system, all within a single scan. Calibration is performed using a flexible multi-purpose calibration board designed to provide necessary reference data.

View Article and Find Full Text PDF

Introduction: A growing body of evidence suggests that hearing loss is a significant and potentially modifiable risk factor for cognitive impairment. Although the mechanisms underlying the associations between cognitive decline and hearing loss are unclear, listening effort has been posited as one of the mechanisms involved with cognitive decline in older age. To date, there has been a lack of research investigating this association, particularly among adults with mild cognitive impairment (MCI).

View Article and Find Full Text PDF

Significance: Peripheral pitting edema is a clinician-administered measure for grading edema. Peripheral edema is graded 0, 1  +  , 2  +  , 3  +  , or 4  +  , but subjectivity is a major limitation of this technique. A pilot clinical study for short-wave infrared (SWIR) molecular chemical imaging (MCI) effectiveness as an objective, non-contact quantitative peripheral edema measure is underway.

View Article and Find Full Text PDF