98%
921
2 minutes
20
Label-free spectromicroscopy methods offer the capability to examine complex cellular phenomena. Electron and X-ray based spectromicroscopy methods, though powerful, have been hard to implement with hydrated objects due to the vacuum incompatibility of the samples and due to the parasitic signals from (or drastic attenuation by) the liquid matrix surrounding the biological object of interest. Similarly, for many techniques that operate at ambient pressure, such as Fourier transform infrared spectromicroscopy (FTIRM), the aqueous environment imposes severe limitations due to the strong absorption of liquid water in the infrared regime. Here we propose a microfabricated multi-compartmental and reusable hydrated sample platform suitable for use with several analytical techniques, which employs the conformal encapsulation of biological specimens by a few layers of atomically thin graphene. Such an electron, X-ray, and infrared transparent, molecularly impermeable and mechanically robust enclosure preserves the hydrated environment around the object for a sufficient time to allow examination of hydrated bio-objects with techniques operating under both ambient and high vacuum conditions. An additional hydration source, provided by hydrogel pads lithographically patterned in the liquid state near/around the specimen and co-encapsulated, has been added to further extend the hydration lifetime. Note that the in-liquid lithographic electron beam-induced gelation procedure allows for addressable capture and immobilization of the biological cells from the solution. Scanning electron microscopy and optical fluorescence microscopy, as well as synchrotron radiation based FTIR and X-ray fluorescence microscopy, have been used to test the applicability of the platform and for its validation with yeast, A549 human carcinoma lung cells and micropatterned gels as biological object phantoms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d1lc00440a | DOI Listing |
J Appl Clin Med Phys
September 2025
Clinical Imaging Physics Group, Duke University Health System, Durham, North Carolina, USA.
Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFHead Face Med
September 2025
Department of Oral and Maxillofacial Surgery, University Hospital Tübingen, Tübingen, Germany.
Background: The treatment of mandibular angle fractures remains controversial, particularly regarding the method of fixation. The primary aim of this study was to compare surgical outcomes following treatment with 1-plate versus 2-plate fixation across two oral and maxillofacial surgery clinics. The secondary aim was to evaluate associations between patient-, trauma-, and procedure-specific factors with postoperative complications and to identify high-risk patients for secondary osteosynthesis.
View Article and Find Full Text PDFBMC Oral Health
September 2025
Oral and Maxillofacial Radiology Department, Cairo university, Cairo, Egypt.
Aim: The purpose of this study was to assess the accuracy of a customized deep learning model based on CNN and U-Net for detecting and segmenting the second mesiobuccal canal (MB2) of maxillary first molar teeth on cone beam computed tomography (CBCT) scans.
Methodology: CBCT scans of 37 patients were imported into 3D slicer software to crop and segment the canals of the mesiobuccal (MB) root of the maxillary first molar. The annotated data were divided into two groups: 80% for training and validation and 20% for testing.
Lipids Health Dis
September 2025
Epidemiology, Medical Faculty, University of Augsburg, Stenglingstr. 2, Augsburg, 86156, Germany.
Background: This study aimed to investigate the gender-specific associations of skeletal muscle mass and fat mass with non-alcoholic fatty liver disease (NAFLD) and NAFLD-related liver fibrosis in two population-based studies.
Methods: Analyses were based on data from the MEGA (n = 238) and the MEIA study (n = 594) conducted between 2018 and 2023 in Augsburg, Germany. Bioelectrical impedance analysis was used to evaluate relative skeletal muscle mass (rSM) and SM index (SMI) as well as relative fat mass (rFM) and FM index (FMI); furthermore, the fat-to-muscle ratio was built.