98%
921
2 minutes
20
Sensitive and selective detection of biomarkers in serum in a short time has a significant impact on health. The enormous clinical importance of developing reliable methods and devices for testing serum levels of cardiac troponin I (cTnI), which are directly correlated to acute myocardial infarction (AMI), has spurred an unmatched race among researchers for the development of highly sensitive and cost-effective sensing formats to be able to differentiate patients with early onset of cardiac injury from healthy individuals with a mean cTnI level of 26 pg mL. Electronic- and electrochemical-based detection schemes allow for fast and quantitative detection not otherwise possible at the point of care. Such approaches rely largely on voltammetric and field-effect-based readouts. Here, we systematically investigate electric and electrochemical point-of-care sensors for the detection of cTnI in serum samples by using the same surface receptors, cTnI aptamer-functionalized CVD graphene-coated interdigated gold electrodes. The analytical performances of both sensors are comparable with a limit of detection (LoD) of 5.7 ± 0.6 pg mL(electrochemical) and 3.3 ± 1.2 pg mL (electric). However, both sensors exhibit different equilibrium dissociation constant (K) values between the aptamer-linked surface receptor and the cTnI analyte, being 160 pg mL for the electrochemical and about three times lower for the electrical approach with K = 51.4 pg mL. This difference is believed to be related to the use of a redox mediator in the electrochemical sensor for readout. The ability of the redox mediator to diffuse from the solution to the surface via the cTnI/aptamer interface is hindered, correlating to higher K values. In contrast, the electric readout has the advantage of being label-free with a sensing limitation due to ionic strength effects, which can be limited using poly(ethylene) glycol surface ligands.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00216-021-03658-0 | DOI Listing |
Talanta
September 2025
Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City, Viet Nam. Electronic address:
Food spoilage poses a global challenge with far-reaching consequences for public health, economic stability, and environmental sustainability. Conventional analytical methods for spoilage detection though accurate are often cost-prohibitive, labor-intensive, and unsuitable for real-time or field-based monitoring. Microfluidic paper-based analytical devices (μPADs) have emerged as a transformative technology offering rapid, portable, and cost-effective solutions for food quality assessment.
View Article and Find Full Text PDFNeurology
October 2025
Alzheimer's Disease and Other Cognitive Disorders Unit, Department of Neurology, Hospital Clínic de Barcelona, Fundació Recerca Clínic Barcelona-IDIBAPS, Spain.
Background And Objectives: α-Synuclein seed amplification assays (αSAAs) can improve the diagnosis of synucleinopathies and detect α-synuclein (αSyn) copathology in vivo in clinical practice. We aimed to evaluate the diagnostic performance of αSAA for detecting αSyn in CSF for diagnosing dementia with Lewy bodies (DLB) in a clinical cohort of cognitively impaired individuals. We explored how the coexistence of Alzheimer disease (AD) and αSyn pathology influences biomarker levels and clinical profiles.
View Article and Find Full Text PDFAnal Chem
September 2025
Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
Compared with efficient anodic luminol electrochemiluminescence (ECL), the disadvantage of cathodic ECL is that luminol cannot be electrochemically oxidized in a direct manner, and the conversion efficiency of dissolved oxygen (DO) as the coreactant to reactive oxygen species (ROS) is poor, which limits its application. Therefore, it is necessary to develop a functional catalyst suitable for the luminol-DO ECL system to directly trigger cathodic ECL. In this study, a coordination microenvironment modulation strategy was proposed.
View Article and Find Full Text PDFJAMA Netw Open
September 2025
Department of Urology, Center for Health Outcomes Research and Dissemination, University of Washington, Seattle.
Importance: Black individuals have a twofold higher rate of prostate cancer death in the US compared with the average population with prostate cancer. Few guidelines support race-conscious screening practices among at-risk Black individuals.
Objective: To examine structural factors that facilitate or impede access to prostate cancer screening among Black individuals in the US.
Cancer Epidemiol Biomarkers Prev
September 2025
Brigham and Women's Hospital, Boston, MA, United States.
Background: Colorectal cancer (CRC) risk models routinely adjust for endoscopic screening because of a) possible confounding with other risk factors and b) possible alteration of natural history of the disease due to adenoma detection and removal.
Methods: In this study, we defined a subject as screen-covered (SC) if a colonoscopy was performed in the past 10 years, and not screen-covered (NSC) otherwise. We created CRC risk models separately for SC and NSC subjects (HRSC, HRNSC) and then obtained a screening-coverage adjusted HR estimate (HRfull) based on a weighted average of ln(HRSC) and ln(HRNSC) with weight equal to the proportion of SC person-time in the NHS population.