98%
921
2 minutes
20
Unlabelled: Electrowetting (EW) response on a dielectric depends on its permittivity value, Young contact angle and voltage amplitude. We present a large change in EW contact angle, from 163° to 80°, on the bilayer dielectric made up of ferroelectric PVDF-HFP with a thin layer of fluoropolymer. The thickness values of both layers were separately optimized for high effective capacitance essential for the large EW response. It reveals that the bilayer with ~ 500 nm thick PVDF-HFP layer and ~ 50 nm thin layer of Teflon results in the maximum value of effective dielectric constant, ≈ 8. Besides this gain, dc-voltage EW response exhibits hysteresis mainly due to polarization in the ferroelectric layer such that, hysteretic offset voltage was found to depend on the applied voltage amplitude and thickness of the dielectrics. Finally, bilayer was subjected to ac-voltage EW in silicone oil for ambient temperature ranging from - 25 to 70 °C. The consistent EW response in this ambient without any degradation/delamination of polymer surface confirmed the durability of the bilayer on the transparent ITO electrodes.
Supplementary Information: The online version contains supplementary material available at 10.1007/s10853-021-06308-z.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8274264 | PMC |
http://dx.doi.org/10.1007/s10853-021-06308-z | DOI Listing |
Macromol Rapid Commun
September 2025
School of Materials and Chemistry, Anhui Agricultural University, Hefei, Anhui, China.
At present, flexible sensors are a hot spot in research and experimental development, but the research on flexible sensors that can be used for human motion monitoring still needs to be deepened. In this work, the green material cellulose acetate (CA) was used as the matrix material, the film was made by electrospinning, crushed by a cell grinder and sodium alginate (SA) was added to promote the uniform dispersion of nanofibers in water, and then methyltrimethoxysilane (MTMS) and MXene nanosheet dispersion were added to make it hydrophobic and good conductivity, and the aerogel precursor solution was prepared, and then the CA/SA/MTMS/MXene aerogel with directional holes was prepared by directional freeze-drying. As a flexible sensor material, it can be used for human wear, monitoring the electrical signals generated by the movement of human joints and other parts, and can still maintain a current of about 0.
View Article and Find Full Text PDFActa Crystallogr E Crystallogr Commun
September 2025
Institut für Anorganische und Analytische Chemie, Technische Universität Braunschweig, Hagenring 30, D-38106 Braunschweig, Germany.
In the structure of the title compound, CHN·CHNOS·CHNOS, the central pyridinic rings are approximately coplanar to the benzo-thia-zole moieties. The phenyl groups are appreciably angled to the central rings [inter-planar angles of 57.30 (3)° for the anion and 79.
View Article and Find Full Text PDFActa Crystallogr E Crystallogr Commun
September 2025
Department of Chemistry, Tulane University, 6400 Freret Street, New Orleans, Louisiana 70118-5698, USA.
The crystal structure of the title compound, [Ni(CHFS)] (), reveals averaged S-C [1.708 (2) Å] and C-C [1.395 (4) Å] bond lengths that are consistent with radical monoanionic ligands paired with a divalent Ni ion.
View Article and Find Full Text PDFActa Crystallogr E Crystallogr Commun
September 2025
Department of Physics Yuvaraja's College University of Mysore,Mysore 570005 Karnataka India.
In the title compound, CHBrClO, the dihedral angle between the 4-bromo-2-chloro-phenyl ring and the aromatic ring of (alk-yloxy)phenyl moiety is found to be 77.21 (2)°. The torsion angle associated with the ester moiety is 173.
View Article and Find Full Text PDFFront Bioeng Biotechnol
August 2025
The Third People's Hospital Affiliated to Fujian University of Traditional Chinese Medicine, Fuzhou City, Fujian, China.
Objective: This study investigates the biomechanical effects of long-term Tai Chi practice on the knee meniscus through biomechanical experimentation and finite element simulation, focusing on practitioners performing Knee Brushing and Twisting Step. The findings aim to establish scientific guidelines for optimizing exercise protocols in middle-aged and elderly populations.
Methods: Twenty male middle-aged and elderly practitioners were recruited, divided into a Beginner Group (BG: n = 10), and an Experienced Group (EG: n = 10).