Article Abstract

In recent years, with the development of precise lathe-cutting equipment, special shaped contact lenses (CL) have been crafted. However, while it is possible to manufacture such a lens, its shape evaluation has not been well-established. We conducted a basic optical experiment using special lenses to measure a spherical lens and nonspherical mold. As the measurement sample, a metal ball, special CL, and a toric-shaped mold were adopted. In order to accurately measure those real shapes, we proposed an algorithm in which the probe light is vertically incident to the sample surface within a numerical aperture of the optical probe. For this algorithm, we developed the specialized time-domain optical coherence tomography (TD-OCT), which was designed to conduct circular scanning while maintaining vertical incidence by driving a two-axis (vertical and horizontal) micro-electromechanical system mirror with a phase difference of 90°. The shape, thickness distribution, and curvature radii of both front and back surfaces of a CL were estimated with this OCT signal analysis and sphere fitting. The shape and curvature radius were evaluated by using the simulated data under the same experimental conditions. They were sufficiently accurate based on the resolution of this OCT. Also, a toric-shaped mold was evaluated by comparing the relationship between each coordinate and intensity of the interference signal. As a result, it is confirmed that the experimental result and the simulated matched well.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.419721DOI Listing

Publication Analysis

Top Keywords

contact lenses
8
toric-shaped mold
8
three-dimensional measurement
4
measurement spherical
4
spherical nonspherical
4
nonspherical shapes
4
shapes contact
4
lenses years
4
years development
4
development precise
4

Similar Publications

Purpose: To report a case of acute and transient accommodative insufficiency after laser in situ keratomileusis (LASIK) due to coronavirus disease 2019 (COVID-19).

Methods: Case report and literature review.

Results: A 36-year-old man complained of acute blurred near vision 7 days after uneventful bilateral hyperopic LASIK, concurrent with the onset of COVID-19 infection.

View Article and Find Full Text PDF

A Clinical Evaluation of Lifitegrast Ophthalmic Solution 5% in Symptomatic Contact Lens Wearers.

Clin Ophthalmol

August 2025

Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada.

Purpose: To evaluate the effectiveness of lifitegrast ophthalmic solution 5% in alleviating end-of-day dryness and discomfort in symptomatic contact lens (CL) wearers.

Patients And Methods: This was an open-label study in symptomatic CL wearers with ratings of ≥40 for end-of-day dryness on a visual analog scale (VAS; 0-100 scale; 100 worst). Participants wore their habitual CLs and instilled lifitegrast twice daily for 12 weeks with lenses removed.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate rotational stability and patient-reported outcomes associated with Tecnis Eyhance toric II "monofocal plus" intraocular lens (IOL), particularly in light of a modified haptic design.

Methods: A prospective, interventional study was conducted with patients undergoing routine cataract surgery and Tecnis Eyhance toric II IOL implantation. The inclusion criteria were topographic corneal astigmatism of 0.

View Article and Find Full Text PDF

Baseline ocular biometrics in children with orthokeratology-induced axial length reduction or elongation.

BMC Ophthalmol

September 2025

Optometry Center, Shaanxi Key Laboratory of Ophthalmology, Xi'an No.1 Hospital (the First Affiliated Hospital of Northwest University), Shaanxi Institute of Ophthalmology, No.30, Fenxiang Alley, South Street, Xi'an, Shaanxi Province, 710002, China.

Purpose: To determine the baseline ocular biometrics in children with axial length reduction after orthokeratology for better myopia control.

Methods: Changes in ocular parameters in 164 subjects who completed one year of Ortho-K treatment were retrospectively reviewed. The subjects were divided into AL reduction (n = 105, ≤ 0 mm/year axial growth) and AL elongation (n = 59, ≥ 0.

View Article and Find Full Text PDF

Introduction: This review aims to analyse the application of the measure methods and measure contents of the outcomes reported in studies on slowing myopia, and the associations between outcomes and study characteristics.

Methods: Publications were identified by a search of seven electronic databases including China National Knowledge Infrastructure, China Biology Medicine, Wanfang database, CQVIP database, PubMed, Cochrane Library and Excerpta Medica Database, for relevant terms like myopia and randomized controlled trial from construction to Sept. 15th, 2023.

View Article and Find Full Text PDF